Mode
Description
Values
“--:--:20”
flashing
Cycle Speed.
If you are in cycle mode, this controls the speed at
which the colors cycle. The higher the number, the slower the colors
will change. If you are not in cycle mode, this setting will be skipped.
Default: 10
Max: 64
Min: 4
Mode
Description
Values
HV Generation Settings (See “HV Settings” note)
“--:--:21”
flashing
HV Target Voltage Higher.
Each press sets the HV target
voltage higher by 5V.
Default: 180
Max: 200
Min: 150
“--:--:22”
flashing
HV Target Voltage Lower.
Each press sets the HV target
voltage lower by 5V.
Default: 180
Max: 200
Min: 150
“--:--:23”
flashing
PWM On Time Longer.
This setting controls how long the PWM
On pulse is. Normally you should not have to change this, but you
can try changing this is the HV generation is noisy or you have
unusual tubes.
Default: 150
Max: 50
Min: 500
“--:--:24”
flashing
PWM On Time Shorter.
This setting controls how long the PWM
On pulse is. Normally you should not have to change this, but you
can try changing this is the HV generation is noisy or you have
unusual tubes.
Default: 150
Max: 50
Min: 500
“--:--:25”
flashing
Increase Minimum dim.
This setting allows you to increase the
minimum brightness you want to have when the clock is fully
dimmed.
Default: 100
Max: 500
Min: 100
“--:--:26”
flashing
Decrease Minimum dim.
This setting allows you to decrease the
minimum brightness you want to have when the clock is fully
dimmed.
Default: 100
Max: 500
Min: 100
“--:--:27”
flashing
Increase Anti-ghosting.
This setting reduces “ghosting” (the
number on the right shows faintly on the digit on the left). This is due
to transients when switching.
Default: 0
Max: 50
Min: 0
“--:--:28”
flashing
Decrease Anti-ghosting.
This setting reduces “ghosting” (the
number on the right shows faintly on the digit on the left). This is due
to transients when switching.
Default: 0
Max: 50
Min: 0
Information Settings
“--:--:29”
flashing
Current case temperature.
Show the current temperature
inside the case (used as part of the temperature compensation for
the clock crystal). Note: This will show 0 if the RTC is not installed.
“--:--:30”
flashing
Clock version.
Show the clock software version.
Digit Test.
Will roll through all digits on all locations to check that
the display is healthy.
Note “HV Settings”:
Before leaving the clock for long periods with a new “HV Generation” setting, check
that neither the MOSFET nor the voltage regulator is running too hot. If either of these components gets too
hot, either adjust the high voltage settings or add a heat sink.