![Arcus DMX-CAN-23 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/arcus/dmx-can-23/dmx-can-23_manual_2965572072.webp)
DMX-CAN Manual
page 72
rev 1.6
6 – Homing
7 – Z Homing
8 – Correction Range Err
9 – Correction Attempt Err
10 – Stall Err
11 – Limit Err
SLT
Returns StepNLoop tolerance value
32-bit
SLT=[value]
Sets StepNLoop tolerance value.
OK
STORE
Store values to flash memory.
OK
SSPD[value]
Set on-the-fly speed change. In order to use this command,
S-curve control must be disabled. Use SCV command to
disable s-curve control.
OK
SSPDM
Return on-the-fly speed change mode
1,2,3,4,5,6,7,8
SSPDM=[value]
Set on-the-fly speed change mode
OK
STOP
Decelerated to stop the motor if in motion. For immediate
stop, use ABORT command
OK
VER
Returns current firmware software version number
VXXX
X[value]
Moves the motor to absolute position value using the HSPD,
LSPD, and ACC values. Maximum allowed incremental
move amount is 262143. For example, if current position is
100000, target move must be between 362143 and -162143
OK
Z+
Homes the motor in positive direction using the Z index
encoder channel ONLY.
OK
Z-
Homes the motor in negative direction using the Z index
encoder channel ONLY.
OK
ZH+
Homes the motor in positive direction using the home switch
and then Z index encoder channel.
OK
ZH-
Homes the motor in negative direction using the home
switch and then Z index encoder channel.
OK
Table 11.0
Error Codes
If an ASCII command cannot be processed by the DMX-CAN, the controller will reply
with an error code. See below for possible error responses:
Error Code
Description
?[Command]
The ASCII command is not understood by the controller
?Bad SSPD Command
SSPD move parameter is invalid
?Enable RS-485 Mode
Modbus mode cannot be set because communication needs to first be set to
RS-485.
?Index out of Range
The index for the command sent to the controller is not valid.
?Motor is not moving
T[] command is invalid because a target position move is not in operation
?Moving
A move or position change command is sent while the controller is
outputting pulses.
?SCV ON
Cannot perform SSPD move because s-curve is enabled
?Speed out of range
SSPD move parameter is out of the range of the SSPDM speed window.
?State Error
A move command is issued while the controller is in error state.
Table 11.1