![Arcus DMX-CAN-23 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/arcus/dmx-can-23/dmx-can-23_manual_2965572026.webp)
DMX-CAN Manual
page 26
rev 1.6
I.
Setup
DMX-CAN configuration values are automatically loaded when the program
is started. All the configuration changes are uploaded and download all at
once. This means that in order for the configuration to become effective,
download button must be pressed. In order for the configuration to be
permanent, store to flash must be pressed.
Click on the Setup button to show the following display box:
Figure 6.13
1.
Polarity values – direction, home, limit, latch input, in position output,
and alarm output values can be selected in this section.
2.
StepNLoop configuration values – See detailed description in the
StepNLoop feature section.
3.
Device ID – Device name ranges from DMK01 to DMK99.
1
11
9
4
5
6
8
2
12
10
3
7
13