![Arcus DMX-CAN-23 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/arcus/dmx-can-23/dmx-can-23_manual_2965572049.webp)
DMX-CAN Manual
page 49
rev 1.6
Table 8.33
Data Description
Value
Description
0
RS-232
1
RS-485
2
CAN
Table 8.34
Object 200B
h
: Bit Rate
This object configures the bit rate for CAN communication.
Object Description
Index
Name
Data Type
Value Range
Access
200B
h
Bit Rate
Unsigned 8
1 - 8
Read/Write
Table 8.35
Data Description
Value
Description
1
10,000
2
20,000
3
50,000
4
100,000
5
125,000
6
250,000
7
500,000
8
800,000
9
1,000,000
Table 8.36
Object 200C
h
: Node ID
The node ID of the CANOpen device can be configured by this object.
Object Description
Index
Name
Data Type
Value Range
Access
200C
h
Node ID
Unsigned 8
1-127
Read/Write
Table 8.37
Object 200D
h
: Clear Error
This object clears the motor and any and all error states. To clear an error, write a 1 to
this object. The device well then clear the error once the trigger has occurred and the
object will be reset to zero, indicating that the error has been cleared. See below for a
timing diagram: