Object Description
Index
Name
Data Type
Value Range
Access
2005
h
Digital Output Boot
Unsigned 8
0 - 7
Read/Write
Table 8.22
To toggle the initial state of a digital output, the corresponding bit must be changed.
Table 8.23 shows the bit mapping for digital outputs.
Bit
Description
0
Digital Output 1
1
Digital Output 2
2
Digital Output 3
Table 8.23
Object 2006
h
: Enable Output Bootup Status
The initial state of the enable output can be defined by configuring this object.
Object Description
Index
Name
Data Type
Value Range
Access
2006
h
Enable Output Boot
Unsigned 8
0 - 1
Read/Write
Table 8.24
Object 2007
h
: Latch Enable
The latch operation performs high speed position capture of both the pulse and encoder
positions. Digital input 2 is used as the latch input trigger.
Note:
When StepNLoop mode is enabled, the position value should be ignored.
Object Description
Index
Name
Data Type
Value Range
Access
2007
h
Latch Enable
Unsigned 8
0 - 1
Read/Write
Table 8.25
Data Description
Value
Description
0
Disable
1
Enable
Table 8.26
Object 2008
h
: Latch Status
This object returns the current latch status.