7
Crankshaft Runout/
Repair Specifications
To use the specifications, first refer to the drawing; then
find the letter indicating the specification and refer to the
chart below the illustration.
8000
NOTE: The proper location for checking crankshaft
runout is the very edge of the straight portion of the
shaft where the oil seal makes contact. From the
illustration, note that three check points are called
out: at either end, out on the taper as shown, and also
on the center bearing race. The crankshaft is still
supported on the outer bearings using V blocks.
728-144A
NOTE: Measure in from the shaft end the specified
amount when checking runout at points D and F. When
checking runout in the center, place indicator on center
of bearing as shown at point E. Maximum runout at any
of the three measuring points is ± 0.002”.
6000
NOTE: The crankshaft must be supported on the
inner bearings using V blocks.
0747-810
Arctic Power Valve (APV)
System Specifications
0735-516
A
± 0.006
B
± 0.006
C
± 0.015
G
Runout D
and F Point
± 0.002
4.751”
2.519”
4.645”
1.181”
D
0.196”
F
0.196”
VALVE POSITION
CYCLE RPM
Mid-Open
Full-Open
67-7500 (Low/High Alt)
77-8500 (Low/High Alt)
APV CABLE LENGTH
CENTER ± 0.039"
1.427” - 6000
1.437" - 8000
Содержание 2014 XF 2-STROKE
Страница 1: ...SNOWMOBILE SERVICE MANUAL 2014 ZR XF M 2 STROKE...
Страница 3: ......
Страница 39: ...36 600_14_2...
Страница 47: ...44 800_12_2...
Страница 122: ...119 Troubleshooting Servomotor SERVO1A14...
Страница 123: ...120 SERVO2rv14...
Страница 152: ...149 0747 413 M Models...
Страница 196: ...Printed in U S A Trademarks of Arctic Cat Inc Thief River Falls MN 56701 p n 2259 956...