2/3/4-wire RTD and thermocouple sensors
Pt100 or Pt1000
Type K, Type J, Type T and Type S
Channels 7 & 8 support mA measurement
9.1.2.4 RS-232 & serial fiber communication module
Table. 9.1.2.4 - 61. Technical data for the RS-232 & serial fiber communication module.
Ports
RS-232
Serial fiber (GG/PP/GP/PG)
Serial port wavelength
660 nm
Cable type
1 mm plastic fiber
9.1.2.5 Double LC 100 Mbps Ethernet communication module
Table. 9.1.2.5 - 62. Technical data for the double LC 100 Mbps Ethernet communication module.
Protocols
Protocols
HSR and PRP
Ports
Quantity of fiber ports
2
Communication port C & D
LC fiber connector
Wavelength 1300 nm
Fiber cable
50/125 μm or 62.5/125 μm multimode (glass)
9.1.3 Display
Table. 9.1.3 - 63. Technical data for the HMI LCD display.
Dimensions and resolution
Number of dots/resolution
320 x 160
Size
84.78 × 49.90 mm (3.34 × 1.96 in)
Display
Type of display
LCD
Color
Monochrome
A
AQ
Q-S214
-S214
Instruction manual
Version: 2.04
115
Содержание AQ-S214
Страница 1: ...AQ S214 Alarm and Indication IED Instruction manual ...
Страница 93: ...Figure 7 1 56 AQ S214 application example A AQ Q S214 S214 Instruction manual Version 2 04 92 ...
Страница 110: ...Figure 8 10 74 Device installation A AQ Q S214 S214 Instruction manual Version 2 04 109 ...
Страница 111: ...Figure 8 10 75 Panel cutout dimensions and device spacing A AQ Q S214 S214 Instruction manual Version 2 04 110 ...