14
2024 series Pneudraulic Installation Tool (HK1077)
Measuring Tool Stroke
nOTe
:
Remove the Nose Assembly from the tool for both of the following procedures.
2024l & 202lV
1.
Cycle the piston all the way forward
and measure
X
.
2.
Cycle and hold the piston back and
measure
y
.
Stroke = X-y
If the stroke is less than 0.850 in (
2.16 cm
),
follow the steps at the end of the
Fill and Bleed
procedure.
Figure 13
2024
&
2024V
1.
Cycle the piston all the way forward and
measure
X
.
2.
Cycle and hold the piston back and
measure
y
.
Stroke = y-X
If the stroke is less than 0.850 in (
2.16 cm
), follow the
steps at the end of the
Fill and Bleed
procedure.
Figure 12