Service Support Spirit
55
Unique Solution
WWW.ARCBRO.COM
Height controller
Arc voltage raising option, fine tuning of control speed, sensitivity of height controller, arc voltage height control,
etc.
Save
Save the modified parameters into parameters space.
Continuous pressing S key, optional external manual control key and manual enable/disable option.
Notes:
1)
When selecting the above parameters, it is required to save the change separately by pressing [F8] key
for validation.
2)
If the password of "1928" is entered in the main window of SETUP, the saving menu of [F8]
will turn to factory setting. In this mode, every modification to parameter will be saved into
the factory setting parameters and the active user parameters. When initializing parameters,
it is suggested to set the factory parameters as active parameters; otherwise, the
modifications will be validated to the active user parameters.
12.2. SETUP(parameter setting)
12.2.1. Speed parameters
In the SETUP submenu, press [F1] key to enter speed parameters setting window, as shown in Fig. 12.2.
Speed parameters include--
Starting speed
----The starting and stop speed of system in X axis and Y axis in mm/min or inch/min. Refer to
Control Parameters for more.
Adjustment time
----The time required for the system to accelerate from starting speed to maximum speed
limit, in seconds.
Uniform acceleration time
---- In the process of acceleration/deceleration, the time needed for linear
acceleration, which is usually little bit smaller than the adjustment time by one tenth approximately.
Maximum speed limit
----The top speed of running system in manual control mode and in execution of G00
command, in mm/min. or inch/min.
Machining speed limit
-----The top machining speed in flame/plasma machining operation, in mm/min. or
inch/min.