Service Support Spirit
20
Unique Solution
WWW.ARCBRO.COM
feedback this signal to CHC, THC and PCB and get order to adjust the torch height accordingly even
if the steel plate surface is rough or not horizontal.
Advantage:
Avoid collision between nozzle and steel plate, extend service life of the torch/nozzle.
9.6.2
Assemble steps:
1.
Attach the flame torch onto the standard torch holder, fix its screw.
2.
Clamp the CHC holder device onto the flame torch, above the standard torch holder.
3.
Fix the screw of the CHC holder well.
4.
Connect the two ends of white Solenoid Valve cable plug.
Note:
If the CHC holder device is not in purchase list, overlook step 2/3/4.
example:
9.6.3
Push down the knob on Wiring Panel of Controller for Flame mode; Set the proper SET VOLTAGE
(default value is 220 for Carbon Steel thickness range 10-30mm),
IHS value
by the screw on the THC,
you can go to the Controller to start an Auto flame cut.
CHC holder
device
Capacity
Wire
Connecter
Solenoid Valve
cable plug