2.8.6 M8-6 test outputs
This function allows you to test the outputs of the pcbt board. It should be noted that this function is
unlocked only when the stove is turned off, or displaying on the display "OFF".
Each press of the button P1 or P2 tenable / disable the output to be tested, according to the table
below. With the P3 button you will proceed to the next test.
Type of test
value
Test ignition coil
On/Off
Test auger
0” ÷ 5”
Test fan
65V ÷ 225V
Test exchanger fan
65V ÷ 225V
2.8.7 M8-7 Reset partials hours
The stove during operation of work, takes into account the partial operating hours. To reset this
value, enter the menu M8-7 and enter the access key 55, then press the button P3. The display will
show "done" to confirm correct reset.
2.8.8 M8-8 Alarm Reset
When the alarm is activated, the electronic stores the type of alarm in progress on one of the 5
banks of memory alarms. To reset the memory banks of the alarms, enter the menu M8-8 and
enter the access key 55, then press the button P3. The display will show "done" (Figure 35) to
confirm proper reset.