2.4.3 LOAD FLAME LIGHT
After the flue gas temperature has reached and exceeded the value in the parameter PR13, the
system switches to power mode, the message "Fire Present" on the display and the LED ON \ OFF
flashes.
In this phase occurs that the temperature remains stable for a timedefined by parameter PR02.
The fan speed is given by the parameter PR17, the auger will turn on for a time given by the
parameter PR05 (LED lit auger intermittent) and the igntion coil is turned off (LEDs glow plug off)
(Figure 24).
Anomalies, stop the card and reports the error. (refer to section 2.6)
fig. 24
2.4.4 Stove in work
After that the flue gas temperature has reached and exceeded the value PR13 and maintained it
for at least a time PR02, the stove reaches the working mode which is that of normal operation.
The display will show the word "on Flame on 5" and the LED ON \ OFF is lit. The power is set by
pressing and holding P2 and the temperature can be set by pressing the P1. (Figure 25).
If the flue gas temperature reaches the threshold set by the parameter PR15, the fan air exchanger
startss. (led exchanger on).
fig. 25
During this phase, after a time given by the parameter PR03, the stove performs a cleaning of the
grate. The display will scroll the message "Pul-grate", the auger is turned on (LED screw on) with a
speed given by the parameter PR09, the smoke fan speed given by parameter PR08. (Figure 7b)
After a time given by the parameter PR12 the stove returns to the working state.
fig. 26
24
Содержание AIRPELLET
Страница 1: ...TECHNICAL MANUAL AIRPELLET 8 KW 10 KW 12 KW Stoves LIBxxx 56 pag Rev 3 15 01 2013...
Страница 2: ......
Страница 51: ...12 1 Modulation...
Страница 52: ...12 2 Stand by 45...
Страница 53: ...12 3 Spegnimento...
Страница 60: ...55 Sede legale Via I Maggio 16 46030 S Giorgio Mantova 0376 372206F Fax 0376 374646...
Страница 61: ...Produzione Via S Giovanni XXIII 105 26865 S Rocco al Porto LODI 0377 569677 0377 56956...