2.4. OPERATING MODE
Below is described the normal operation of the controller regularly installed in a stove air with reference to
the functions available to the user. Before turning on the stove, the display appears as in Fig. 21.
fig. 21
2.4.1 TURNING ON THE STOVE
Turn the stove on press P3 for a few seconds. The ignition is indicated in the display with the message
"START" as shown below and the LED will flash ON/OFF.
In that condition the stove is placed in the state of preheating, turns on the ignition coil (visible from the
ignition coil light) and the flue gas fan (fig. 22).
.Any anomalies during the ignition phase, are shown on the display and the stove goes into an alarm state.
(refer to paragraph 2.6)
fig. 22
2.4.2 Loading the pellet
After about 10 seconds starts the loading phase pellet, will scroll the message "LOAD PELLET" and the LED
ON \ OFF is flashing.
In a first step the auger provides to load the pellets in the grate for a time given by the parameter PR40 (LED
auger turned on), the speed of the fan is defined by parameter PR42 and the ignition coil is always turned on
(lit LED of ignition coil).
In the second phase, the elapsed time of the parameter PR40, the auger is turned off (LEDs auger off) for a
time given by the parameter PR41, while the speed of the fan and the ignition coil remain in its previous
state. If the ignition does not take place after that stage, the auger on again for a period given by parameter
PR04, the speed of the fan is given by the parameter PR16 and the glow plug remains lit (fig. 23).
fig. 23
23
Содержание AIRPELLET
Страница 1: ...TECHNICAL MANUAL AIRPELLET 8 KW 10 KW 12 KW Stoves LIBxxx 56 pag Rev 3 15 01 2013...
Страница 2: ......
Страница 51: ...12 1 Modulation...
Страница 52: ...12 2 Stand by 45...
Страница 53: ...12 3 Spegnimento...
Страница 60: ...55 Sede legale Via I Maggio 16 46030 S Giorgio Mantova 0376 372206F Fax 0376 374646...
Страница 61: ...Produzione Via S Giovanni XXIII 105 26865 S Rocco al Porto LODI 0377 569677 0377 56956...