Page 14
C. Inline Push Button Configuration (Transmitter Toggle)
The push button arrangement for inline push button setup starts from top to bottom and then
from right column to left column (refer to Fig. 10 below). To set inline push button
configuration please refer to JP4 and JP5 jumpers setting on page 28. With inline push buttons
configuration, PB1 & PB2 still corresponds to output relay K1~K4, PB3 & PB4 corresponds to
relay K5~K8, etc…
(Fig. 10)
DIP
PB7
PB8
PB9
PB10 PB11
PB12
64
00000000 Normal Normal Normal Normal Normal
Normal
65
00000101 Normal Normal Normal LED 4 Normal Normal
66
00010100 Normal Normal LED 3 LED 4 Normal Normal
67
00010101 Normal LED 2 LED 3 LED 4 Normal Normal
68
00010110
LED 1 LED 2 LED 3 LED 4 Normal Normal
69
00001001 Normal Normal Normal Normal LED 4 Normal
70
00010111 Normal Normal Normal LED 3 LED 4 Normal
71
00011000 Normal Normal LED 2 LED 3 LED 4 Normal
72
00011001 Normal LED 1 LED 2 LED 3 LED 4 Normal
73
00001101 Normal Normal Normal Normal Normal
LED 4
74
00011010 Normal Normal Normal Normal LED 3 LED 4
75
00011011 Normal Normal Normal LED 2 LED 3 LED 4
76
00011100 Normal Normal LED 1 LED 2 LED 3 LED 4
*
PB7…PB12
→
Push button number
*
Normal
→
Normal momentary contact
* LED 1…LED 4
→
Transmitter toggled with designated LED Display
Содержание FLEX 12EX