Page 28
JP1
JP2
JP3
JP4
JP5
JP6
JP7
5. Jumper
Settings
Jumper settings are applied to functions such as Start command, transmitter push button layout,
system information (serial number/ID code) programming, and system testing. The jumpers #3 ~ #7
are located on the decoder module above the six (6) dip-switches (refer to Fig.16 below).
(Fig. 16)
▇
Manufacture preset
Jumper Settings
Function
JP3
(Blank)
After 1 or 3 minutes of transmitter inactivity (MAIN deactivated), press
any push button on the transmitter to reactivate the receiver MAIN.
JP3
(Inserted)
After 1 or 3 minutes of transmitter inactivity (MAIN deactivated), rotate
the transmitter power key-switch to “START” position to reactivate the
receiver MAIN.
JP4
(Blank)
JP5
(Blank)
Standard right-to-left push button configuration for all models.
JP4
(Inserted)
JP5
(Blank)
In-line push button configuration (top to bottom) for FLEX 8ES/EX.
JP4
(Blank)
JP5
(Inserted)
In-line push button configuration (top to bottom) for FLEX 12ES/EX.
JP4
(Inserted)
JP5
(Inserted)
In-line push button configuration (top to bottom) for FLEX 4ES/EX.
JP6
(Blank)
Program system serial number/ID code and channel from decoder module
to I-CHIP.
JP6
(Inserted)
Program system serial number/ID code and channel from I-CHIP
to decoder module.
JP7
(Inserted)
For system test only, receiver MAIN disabled.
Содержание FLEX 12EX
Страница 1: ...FLEX12EX User s Manual ...