Page 29
COM
1
2
3
4
6. I-CHIP Programming Port
(Fig. 17)
I-CHIP programming port located on the decoder module (refer to Fig. 17 above) inside the receiver
is designed for the purpose of transferring system serial number/ID code either from I-CHIP to
receiver or from receiver to I-CHIP. If you wish to transfer system information from receiver to
I-CHIP, just insert the I-CHIP onto the programming port (JP6 jumper not inserted), wait until the
Status LED on the decoder module turned constant green (within 2 seconds), and then take the
I-CHIP out of the programming port (programming completed). At this time the I-CHIP should also
possess the same serial number/ID code as the receiver. If the Status LED on the decoder module
displayed a constant red light after inserting the I-CHIP (programming failed), then you must
reinsert the I-CHIP one more time. On the other hand, if you wish to transfer system information
from I-CHIP to receiver, then you must first insert JP6 jumper prior to inserting the I-CHIP, then
wait for the green light to appear on the Status LED. At this time the receiver should also possess
the same system information as the I-CHIP. Please note that the receiver unit must be powered in
order to proceed with the programming.
7. Voltage
Settings
Prior to installation always check the voltage setting is correct for your application (refer to Fig. 18
below).
Position
1
→
110~120VAC
Position
2
→
220~240VAC
or
24VAC*
Position
3
→
380VAC or 42VAC*
Position
4
→
400~460VAC or 48VAC* or 12~24VDC**
*
For
system
with
24/42/48VAC
power
supply.
(Fig. 18)
** For system with 12~24VDC power supply.
F9 and F10 power fuse ratings:
FUSE # 110~120VAC 220~240VAC
380VAC
400~460VAC
24VAC
42 & 48VAC 12~24VDC
F9
1.0A (red)
1.0A (red)
1.0A (red)
0.5A (blue) 3.0A (yellow) 2.0A (purple) 2.0A (purple)
F10
1.0A (red)
1.0A (red)
1.0A (red)
0.5A (blue) 3.0A (yellow) 2.0A (purple) 2.0A (purple)
* Output relay fuse
→
5.0A (clear)
Содержание FLEX 12EX