The opening must be framed to provide adequate support and prevent air from
being drawn from the roof cavity. Framing stock 20mm or more in thickness must be
used. Remember to provide an entrance hole for the power supply wire. See FIG.05.
The 362*362mm (+/-2mm) or 400*400mm (+/-2mm) roof opening is part of the
return air duct and must be polished according to the industry standard.
Take out the roof air conditioner from the carton.
Place the roof air conditioner on the vehicle roof.
Lift and place roof air conditioner over the prepared opening using the EVA gasket as
a guide. The condenser coil goes toward the rear of the vehicle. See FIG.06.
This roof air conditioner weighs approximately 37Kg. To prevent back injury, use
a mechanical hoist to place air conditioner on roof.
5.3 Placing roof air conditioner on the roof
ATTENTION!
MIN 20MM
FRAME OPENING
PROVIDE HOLE
FOR WIRING
05