Unscrew and remove the roof vent.
Remove all caulking compound around opening.
Seal all screw holes and seams where the roof gasket will be located. Use a good
grade of all weather sealer.
A 362*362mm (+/-2mm) or 400*400mm (+/-2mm) opening must be cut through
the roof and ceiling of the vehicle if the existing vents will not be used. It is
recommended this opening be located between roof reinforcing members.
There may be electrical wiring between the roof and the ceiling. Disconnect 220V
AC power cord and the positive (+) 12V DC terminal at the supply battery. Failure
to follow this instruction may create a shock hazard causing death or severe
personal injury.
Mark a 362*362mm (+/-2mm) or 400*400mm (+/-2mm) square on the roof and
carefully cut the opening. Using the roof opening as a guide, cut the matching hole in
the ceiling. See FIG.04.
5.2 Roof preparation
Roof vent removal:
New opening :
(installation other than vent opening)
DANGER!
Opening instructions:
Wiring requirements:
a.
b.
If the opening exceeds 365*365mm, it will be necessary to install spacers.
If the opening is less than 358*358mm, it must be enlarged.
Route a copper 2.5mm², with ground, supply line from the fuse or circuit breaker box
to the roof opening.
The power supply must be on a separate 20 Amp Time Delay Fuse or HACR Circuit
Breaker.
Make sure at least 380mm of wire extends into the roof opening. This insures easy
a.
b.
c.
a.
b.
Содержание KAC 25
Страница 12: ...CN 12 04 383mm 958mm 720mm 364mm 560mm 479mm ...
Страница 16: ...CN 16 08 09 ...
Страница 25: ...Make A Difference 卓 尔 不 凡 CN 11 0 电路接线图 25 KAC 33 接线图 ...
Страница 26: ...CN 26 KAC 25 接线图 ...
Страница 28: ...CN 28 上风管 底板 16 17 18 21 19 22 20 23 下风管 显示板 面板固定板 面板 百叶 回风面罩 16 17 18 19 20 21 22 23 ...
Страница 56: ...EN KAC 25 56 ...