Par.
ADVANCED SETTINGS
"IMPLEMENT"
11.4.10 Alarms
Set monitor job alarms.
NOZZLE ALARMS
• Nozzle wear check
Enable the function to set the nozzle wear limit percentage.
Check enabled
Check disabled
This alarm can be enabled ONLY if the system features both flowmeter and pressure sensor
• Nozzle wear limit percentage
Set the acceptable threshold: the monitor compares the effective rate read by the flowmeter and the one calculated by the pressure sensor.
When the difference between the two rate values exceeds the set percentage, the alarm is triggered.
• Minimum pressure alarm
• Maximum pressure alarm
Allows to enable/disable minimum and maximum pressure alarms for the nozzles in use.
- Select the item you wish to set up.
- Enable / disable the alarm
(
Alarm enabled /
Alarm disabled)
.
- Repeat the setup for each alarm.
Outside the range set in
Minimum pressure
/
Maximum pressure
menus (par. 11.4.6 Nozzles data), the computer triggers an alarm.
FLOWMETER ALARMS
• Minimum flowrate alarm
• Maximum flowrate alarm
Allows to enable/disable minimum and maximum flowrate alarms for the flowmeter.
- Select the item you wish to set up.
- Enable / disable the alarm
(
Alarm enabled /
Alarm disabled)
.
- Repeat the setup for each alarm.
Outside the range set in the
Minimum flowrate
/
Maximum flowrate
menus (par. 11.4.2 Flowmeter), the computer triggers an alarm.
REV COUNTER ALARMS
• Minimum rotation speed alarm
• Maximum rotation speed alarm
Allows to enable/disable minimum and maximum speed alarms for the rev counter.
- Select the item you wish to set up.
- Enable / disable the alarm
(
Alarm enabled /
Alarm disabled)
.
- Repeat the setup for each alarm.
Outside the range set in the
Minimum rotation speed
/
Maximum rotation speed
menus (par. 11.4.8 Rev counter), the computer triggers an alarm.