Troubleshooting
-
Control
Valve
Problem
Cause
Correction
8. Softener fails to draw brine.
A. Drain line
flow control is
plugged.
A. Clean drain line
flow control.
B. Injector is plugged.
B. Clean injector
C. Injector screen plugged.
C. Clean screen.
D. Line pressure is too low.
D. Increase line pressure to 20 P.S.I.
E. Internal control leak
E. Change seals, spacers, and piston
assembly.
F. Service adapter did not cycle.
F. Check drive motor and switches.
9. Control cycles continuously.
A. Misadjusted, broken, or shorted
switch.
A. Determine if switch or timer is faulty
and replace it, or replace complete
power head.
10. Drain
flows continuously.
A. Valve is not programming
correctly.
A. Check timer program and positioning
of control. Replace power head assembly
if not positioning properly.
B. Foreign material in control.
B. Remove power head assembly and
inspect bore. Remove foreign material
and check control in various regeneration
positions.
C. Internal control leak.
C. Replace seals and piston assembly.
General
Service
Hints
For
Meter
Control
Problem:
Softener
delivers
hard
water
Reason:
Reserve capacity has been exceeded.
Correction:
Check salt dosage requirements and reset program wheel to provide additional reserve.
Reason:
Meter is not measuring
flow.
Correction:
Check meter with meter checker.
Page 31
Содержание WaterPro
Страница 20: ...6700XTR Powerhead Assembly 61501 6700_REVC Page 20...
Страница 22: ...Control Valve Assembly 61500 6600 6700_DF_REVB Page 22...
Страница 32: ...Water Conditioner Flow Diagrams Service Position Backwash Position Page 32...
Страница 33: ...Water Conditioner Flow Diagrams Brine Slow Rinse Position Rapid Rinse Page 33...
Страница 34: ...Water Conditioner Flow Diagrams Brine Tank Fill Position Page 34...
Страница 35: ...Valve Wiring Diagram Page 35 42139_REVA...
Страница 37: ...Notes Page 37...
Страница 38: ...Notes Page 38...
Страница 39: ...Notes Page 39...