Master
Programming
Mode
11.
Regeneration
Cycle
Step
Programming
This program step programs the Regeneration Cycle step times 1 through 5. Please refer to the chart below
for regeneran
t flow default cycle steps and times.
Regenerant
Flow
Cycle
1
Time
Cycle
2
Time
Cycle
3
Time
Cycle
4
Time
Cycle
5
Time
Down Flow
Back Wash
10
Minutes
Brine
& Slow
Rinse
1 Hour
Rapid
Rinse
10
Minutes
Brine Tank Fill
12 Minutes
N/A
N/A
Back Wash Filter
Back Wash
15
Minutes
Draw
0
Settling
Rinse
10
Minutes
Re
fill
0
N/A
N/A
UF Back Wash
Backwash
10
Minutes
Brine
& Slow
Rinse
1 Hour
Rapid
Rinse
10
Minutes
Brine Tank Fill
12 Minutes
N/A
N/A
Down Flow Double
Backwash
Back Wash
10
Minutes
Brine
& Slow
Rinse
1 Hour
Back
Wash
10
Minutes
Rapid Rinse
10 Minutes
Brine Tank Fill
12 Minutes
Up Flow
Brine Rinse
60
Back
Wash
10
Rapid
Rinse
10
Minutes
Brine Tank Fill
12 Minutes
N/A
N/A
Up
flow Variable Fill
Brine Rinse
Variable
Pause
60
minutes
Brine
Rinse
60
Minutes
Back Wash
12 Minutes
Rapid Rise
10 Minutes
12.
Media
Volume
This program step sets the volume of the media in the resin tank.
— Press the Shift button to select the digit you want to modify.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
13.
Salt
Dosage
This program step sets the salt dosage in the unit.
— Press the Shift button to select the digit you want to modify.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
14.
Brine
Line
Flow
Control
Size
This program step allows the selection of the desired brine line
flow control size in the unit (must match
physical brine line
flow control).
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
15.
Auxiliary
Relay
Output
The next two displays are part of a series of settings used to program the optional relay output. The
first
setting turns the output on/off during regeneration only. The second turns the output on during service only,
every time a set volume of water used has accumulated.
NOTE:
When
auxiliary
outputs
are
in
the
OFF
(default)
setting,
press
the
Up
or
Down
buttons
to
set
the
first
setting.
Then
press
the
Extra
Cycle
button
to
advance
to
the
second
setting.
CAUTION:
Before
entering
Master
Programming,
please
contact
your
local
professional
water
dealer.
Page 15
Содержание WaterPro
Страница 20: ...6700XTR Powerhead Assembly 61501 6700_REVC Page 20...
Страница 22: ...Control Valve Assembly 61500 6600 6700_DF_REVB Page 22...
Страница 32: ...Water Conditioner Flow Diagrams Service Position Backwash Position Page 32...
Страница 33: ...Water Conditioner Flow Diagrams Brine Slow Rinse Position Rapid Rinse Page 33...
Страница 34: ...Water Conditioner Flow Diagrams Brine Tank Fill Position Page 34...
Страница 35: ...Valve Wiring Diagram Page 35 42139_REVA...
Страница 37: ...Notes Page 37...
Страница 38: ...Notes Page 38...
Страница 39: ...Notes Page 39...