Master

 

Programming

 

Mode

 

 

 

11.

 

Regeneration

 

Cycle

 

Step

 

Programming

 

 

This program step programs the Regeneration Cycle step times 1 through 5. Please refer to the chart below

 

for regeneran

t flow default cycle steps and times.

 

 
 
 
 

 

Regenerant

 

Flow

 

 

Cycle

 

1

 

 

Time

 

 

Cycle

 

2

 

 

Time

 

 

Cycle

 

3

 

 

Time

 

 

Cycle

 

4

 

 

Time

 

 

Cycle

 

5

 

 

Time

 

 

 

Down Flow

 

 

 

Back Wash

 

 

 

10

 

Minutes

 

 

Brine

 

& Slow

 

Rinse

 

 

 

1 Hour

 

 

 

Rapid

 

Rinse

 

 

 

10

 

Minutes

 

 

 

Brine Tank Fill

 

 

 

12 Minutes

 

 

 

N/A

 

 

 

N/A

 

 

 

Back Wash Filter

 

 

 

Back Wash

 

 

15

 

Minutes

 

 

 

Draw

 

 

 

0

 

 

Settling

 

Rinse

 

 

10

 

Minutes

 

 

 

Re

fill

 

 

 

0

 

 

 

N/A

 

 

 

N/A

 

 

 

UF Back Wash

 

 

 

Backwash

 

 

 

10

 

Minutes

 

 

Brine

 

& Slow

 

Rinse

 

 

 

1 Hour

 

 

 

Rapid

 

Rinse

 

 

 

10

 

Minutes

 

 

 

Brine Tank Fill

 

 

 

12 Minutes

 

 

 

N/A

 

 

 

N/A

 

 

 

Down Flow Double

 

Backwash

 

 

 

Back Wash

 

 

 

10

 

Minutes

 

 

Brine

 

& Slow

 

Rinse

 

 

 

1 Hour

 

 

 

Back

 

Wash

 

 

 

10

 

Minutes

 

 

 

Rapid Rinse

 

 

 

10 Minutes

 

 

 

Brine Tank Fill

 

 

 

12 Minutes

 

 

 

Up Flow

 

 

 

Brine Rinse

 

 

 

60

 

 

Back

 

Wash

 

 

 

10

 

 

Rapid

 

Rinse

 

 

10

 

Minutes

 

 

 

Brine Tank Fill

 

 

 

12 Minutes

 

 

 

N/A

 

 

 

N/A

 

 

 

Up

flow Variable Fill

 

 

 

Brine Rinse

 

 

 

Variable

 

 

 

Pause

 

 

60

 

minutes

 

 

Brine

 

Rinse

 

 

60

 

Minutes

 

 

 

Back Wash

 

 

 

12 Minutes

 

 

 

Rapid Rise

 

 

 

10 Minutes

 

 

 

12.

 

Media

 

Volume

 

 

This program step sets the volume of the media in the resin tank.

 

—  Press the Shift button to select the digit you want to modify.

 

—  Press the Up or Down buttons to adjust this value.

 

—  Press the Extra Cycle button.

 

 

13.

 

Salt

 

Dosage

 

 

This program step sets the salt dosage in the unit.

 

 

—  Press the Shift button to select the digit you want to modify.

 

—  Press the Up or Down buttons to adjust this value.

 

—  Press the Extra Cycle button.

 

 

14.

 

Brine

 

Line

 

Flow

 

Control

 

Size

 

 

This program step allows the selection of the desired brine line 

flow control size in the unit (must match

 

physical brine line 

flow control).

 

—  Press the Up or Down buttons to adjust this value.

 

 

—  Press the Extra Cycle button.

 

 

15.

 

Auxiliary

 

Relay

 

Output

 

 

The next two displays are part of a series of settings used to program the optional relay output. The 

first

 

setting turns the output on/off during regeneration only. The second turns the output on during service only,

 

every time a set volume of water used has accumulated.

 

NOTE:

 

When

 

auxiliary

 

outputs

 

are

 

in

 

the

 

OFF

 

(default)

 

setting,

 

press

 

the

 

Up

 

or

 

Down

 

buttons

 

to

 

set

 

the

 

first

 

setting.

 

Then

 

press

 

the

 

Extra

 

Cycle

 

button

 

to

 

advance

 

to

 

the

 

second

 

setting.

 

 
 
 
 
 
 
 

CAUTION:

 

Before

 

entering

 

Master

 

Programming,

 

please

 

contact

 

your

 

local

 

professional

 

water

 

dealer.

 

 

Page 15

 

Содержание WaterPro

Страница 1: ...ener Service Manual AQUAPRO WATER SYSTEMS LLC 508 PUTTING LANE JACKSON MO 63755 LINE 573 243 1800 CELL 573 225 6968 AQUAPROSYSTEMS ATT NET AUFDENBERG ENTERPRISES IMPORTANT Fill in Pertinent Informatio...

Страница 2: ...mation from a number of suppliers not known at the time of manufacture This product should be installed by a plumbing professional This unit is designed to be installed on potable water systems only T...

Страница 3: ...sage BLFC Size Auxiliary Relay Auxiliary Relay Start 1 Auxiliary Relay End 1 Auxiliary Relay Start 2 Auxiliary Relay End 2 Chemical Pump CPO Aux Relay Volume CPO Aux Relay Down Flow Up Flow Down ow Do...

Страница 4: ...s 20 6 m 5 Cut the 1 distributor tube 1 050 O D ush with top of each tank 6 Lubricate the distributor o ring seal and tank o ring seal Place the main control valve on the tank NOTE Use only non petrol...

Страница 5: ...SRV with RGQ Service SRV SRV will display when the unit is in service LED Status Lights Blue LED Illuminates while the unit is in service and no errors exist The unit will always be in service unless...

Страница 6: ...been reached Setting the Time of Day 1 Press and hold the Up or Down button for 2 seconds 2 Press the Shift button to select the digit you want to modify 3 Press the Up or Down buttons to adjust the...

Страница 7: ...ring a power failure and will be restored upon power re application Time is kept during a power failure and time of day is adjusted upon power up as long as power is restored within 12 hours NOTE The...

Страница 8: ...Shift button to select the digit you want to modify Entering Master Programming Mode 1 Press and hold the Shift and Up buttons for 5 seconds OR 2 Set the Time of Day display to 12 01 P M or 12 01HR T...

Страница 9: ...rogramming Mode Flow Chart NOTE Depending on current option settings some displays cannot be viewed or set CAUTION Before entering Master Programming please contact your local professional water deale...

Страница 10: ...ogramming Mode Flow Chart NOTE Depending on current option settings some displays cannot be viewed or set CAUTION Before entering Master Programming please contact your local professional water dealer...

Страница 11: ...ogramming Mode Flow Chart NOTE Depending on current option settings some displays cannot be viewed or set CAUTION Before entering Master Programming please contact your local professional water dealer...

Страница 12: ...g press the Diagnostic button NOTE If no keypad activity is made for 5 minutes while in the Master Programming Mode or if there is a power failure no changes will be made and the unit will go back to...

Страница 13: ...t can be removed Press the Shift button to select the digit you want to modify Press the Up or Down buttons to adjust this value Press the Extra Cycle button 6 Feed Water Hardness This program step is...

Страница 14: ...ttons to adjust this value Press the Extra Cycle button 9 Regeneration Day Override This program step sets the maximum amount of time in days the unit can be in service without a regeneration Press th...

Страница 15: ...the volume of the media in the resin tank Press the Shift button to select the digit you want to modify Press the Up or Down buttons to adjust this value Press the Extra Cycle button 13 Salt Dosage T...

Страница 16: ...e on time in seconds of the output Activate output after volume set is reached Press the Shift button to select the digit you want to modify Press the Up or Down buttons to adjust this value Press the...

Страница 17: ...e the cursor and change the value of the numbers Press the Extra Cycle button to proceed to the next step NOTE Feed Water Hardness will not be shown in Volume Override or Time Clock system types 3 Set...

Страница 18: ...ing Diagnostic Mode 1 Press and release the D button 2 Press the Extra Cycle button once per display until all displays are viewed and the normal display screen appears 3 Press and release the D butto...

Страница 19: ...ycle button 2 Peak Flow Rate This program step displays the peak ow rate 1 minute average since the last regeneration Press the Extra Cycle button 3 Totalizer This program step displays the total volu...

Страница 20: ...6700XTR Powerhead Assembly 61501 6700_REVC Page 20...

Страница 21: ...6700 15 1 19079 Washer Friction 16 1 17438 Cam 6600 Down ow 1 40609 Cam Double Backwash D F 17 1 15151 Screw Flat Head St 6 20 x 3 4 18 2 10218 Switch Micro 19 1 10302 Insulator Limit Switch 20 2 1787...

Страница 22: ...Control Valve Assembly 61500 6600 6700_DF_REVB Page 22...

Страница 23: ...1 11973 Spring Brine Valve 22 1 11981 01 Ring Retaining 23 1 12088 Washer Flow 2 4 GPM 24 1 12094 Washer Flow 25 GPM 25 1 12550 Quad Ring 009 26 1 12626 Seat Brine Valve 27 1 12638 O ring 013 Injecto...

Страница 24: ...Electronic Meter Cap 3 1 41055 Plate Intermediate 4 1 13847 O ring 137 Std Meter 5 5 17798 Screw Slot Hex Wsh Hd 6 1 13821 Body Meter 5600 7 1 13509 Impeller Meter 8 4 12473 Screw Hex Wsh 10 24 x 5 8...

Страница 25: ...Quantity Part No Description 1 2 13305 O ring 119 2 2 13255 Clip Mounting 3 2 13314 Screw Slot Ind Hex 8 18 x 60 4A 1 18706 Yoke 1 NPT Plastic 18706 02 Yoke 3 4 NPT Plastic 4B 1 41027 01 Yoke 3 4 NPT...

Страница 26: ...05 Seal By pass 560CD 3 1 11972 Plug By pass 4 1 11978 Plate By pass Top 5 1 11979 02 Lever By pass Black 6 1 11986 Plate By pass Bottom 7 8 15727 Screw Hex Wsh Hd 10 24 x 1 2 8 1 13604 03 Label By pa...

Страница 27: ...l 3 8 Brass 3 1 11566 Ball Stop Slow Fill 4 1 10328 Fitting Elbow 90 Deg 1 4 NPT x 3 8 T 5 2 10332 Fitting Insert 3 8 6 2 10330 Fitting Sleeve 3 8 Celcon 7 2 10329 Fitting Tube 3 8 Nut Brass 8 1 10186...

Страница 28: ...1 19805 Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w o O ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Re...

Страница 29: ...wer outage has occurred Either wait 5 minutes for blinking to stop or press any key on the keypad B Unit not responding after going into regeneration B Verify the unit is con gured correctly ex wiring...

Страница 30: ...ing B Excessive water in brine tank B See problem 7 4 Loss of water pressure A Iron buildup in line to water conditioner A Clean line to water conditioner B Iron buildup in water conditioner B Clean c...

Страница 31: ...faulty and replace it or replace complete power head 10 Drain ows continuously A Valve is not programming correctly A Check timer program and positioning of control Replace power head assembly if not...

Страница 32: ...Water Conditioner Flow Diagrams Service Position Backwash Position Page 32...

Страница 33: ...Water Conditioner Flow Diagrams Brine Slow Rinse Position Rapid Rinse Page 33...

Страница 34: ...Water Conditioner Flow Diagrams Brine Tank Fill Position Page 34...

Страница 35: ...Valve Wiring Diagram Page 35 42139_REVA...

Страница 36: ...167 Spacer Brine Valve 13302 O ring 014 16098 Washer Nylon Brine 13172 Brine Valve Stem 12626 Seat Brine Valve Floats 60028 XX 2300 Blue White Float 60068 XX 2310 Blue White Float Injector 60084 XX In...

Страница 37: ...Notes Page 37...

Страница 38: ...Notes Page 38...

Страница 39: ...Notes Page 39...

Страница 40: ...AQUAPRO WATER SYSTEMS LLC 508 PUTTING LANE JACKSON MO 63755 LINE 573 243 1800 CELL 573 225 6968 AQUAPROSYSTEMS ATT NET AUFDENBERG ENTERPRISES P N 42132 Rev C...

Отзывы: