Master
Programming
Mode
3.
Regenerant
Flow
This program step selects how the regeneran
t flows through the tank (must match cam). The selections
available will vary depending on the previously chosen valve model.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
4.
Display
Format
This program step selects the display format.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
5.
Unit
Capacity
This program step selects the timer
’s total capacity of hardness that can be removed.
— Press the Shift button to select the digit you want to modify.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
6.
Feed
Water
(Hardness)
This program step is used to set the feed water hardness. The system will automatically calculate volume
remaining based on the unit capacity, capacity safety factor, and feed water hardness entered.
— Press the Shift button to select the digit you want to modify.
— Press the Up or Down buttons to adjust this value.
— Press the Extra Cycle button.
NOTE:
Feed
Water
Hardness
will
not
be
shown
in
Volume
Override
or
Time
Clock
system
types.
CAUTION:
Before
entering
Master
Programming,
please
contact
your
local
professional
water
dealer.
Page 13
Содержание WaterPro
Страница 20: ...6700XTR Powerhead Assembly 61501 6700_REVC Page 20...
Страница 22: ...Control Valve Assembly 61500 6600 6700_DF_REVB Page 22...
Страница 32: ...Water Conditioner Flow Diagrams Service Position Backwash Position Page 32...
Страница 33: ...Water Conditioner Flow Diagrams Brine Slow Rinse Position Rapid Rinse Page 33...
Страница 34: ...Water Conditioner Flow Diagrams Brine Tank Fill Position Page 34...
Страница 35: ...Valve Wiring Diagram Page 35 42139_REVA...
Страница 37: ...Notes Page 37...
Страница 38: ...Notes Page 38...
Страница 39: ...Notes Page 39...