13
NOTE: Flex conduit is recommended for connecting the electrical supply wires to the
heat pump so that the front panel may be removed easily for servicing.
2
、
The requirements for heat pumps include the following
Appropriate site location and clearances
;
Sufficient air ventilation
;
Proper electrical wiring
;
Adequate water flow
;
NOTE: This manual provides the information needed to meet these requirements.
Review all application and installation procedures completely before continuing the
installation
。
3
、
Clearances
Avoid placing the heat pump in locations where it can cause damage by water or
condensate leakage. If this is not possible, provide a suitable drain pan to catch and
divert any leakage. All criteria given in the following sections reflect minimum
clearances. However, each installation must also be evaluated, taking into account
the prevailing local conditions such as proximity and height of walls, and proximity to
public access areas.
D
D
C
B
A
A
B
C
80cm
150cm
30cm
80cm
60cm
15cm
100cm
60cm
Minimum
Clearances for
Operation
Recommended
Clearances for
Serviceability
4
、
Equipment Pad
Place the heat pump on a flat slightly itched surface, such as a concrete or fabricated
slab (pad).This allows proper drainage of condensation and rain water from the base
of the unit. If possible, the pad should be placed at the same level or slightly higher
than the filter system equipment pad.