controller will ensure that whether need to heat according to water temperature,
otherwise the current time is in or not in the setting period of time, if it is not in the
setting period of time, then the controller will not heat whether the water temperature
is high or low.
The controller can be set 3 heat periods of time at most, if you don¡t need some
periods of time, you can set the starting time and ending time which you don¡t need as
¡OFF¡.
In addition, if the ending time is earlier than starting time, the controller considers this
ending time is next day. For example, the period of time is ¡22:00¡to¡03:30¡, the
controller considers it as 22:00 at night to 03:30 next day.
Probation time
A probation time can be set (F87), the controller can add up the running time after
power is on, if the accumulative running time is over the probation time, the controller
will stop and display the alarm code A99, if you want to eliminate the limit of probation
time, set the F87 to ¡OFF¡, also you can use the F86 to clear the accumulative
running time, and you can try to use it again. The parameter F85 can be used to
examine the accumulative running time of the controller (hour).
Password
In order to prevent irrespective persons from changing the parameters, you can set a
password (F80), and if you have set a password, the controller will hint you to enter
the password after you press the key ¡M¡ for 5 seconds, you must enter the correct
password, and then you can set the parameters. If you don¡t need the password, you
can set F80 to ¡OFF¡. Notice that you must remember the password, and if you forget
the password, you can not enter the set state.
Wiring Diagram: