6
refer to the
temperature
controlling
F13
Max setting
temperature
-58 - 302
35
℃
/
℉
Notice: the
controller will follow
the rule of
F14<F11<F13
forcibly, if you find
out that one
parameter can not
be adjusted, it is
because the
parameter is
limited by other
parameters, you
must first adjust
other parameters
F14
Min setting
temperature
-58 ¨ 302
10
℃
/
℉
F17
Auto mode
temperature
difference
3 - 20
3
℃
/
℉
If
F17<F12,F17=F12
admitted
F18
Evaporator
sensor
adjustment
-20 ¨ 20
0.0
℃
/
℉
Adjust the outdoor
machine sensor
bias
F19
Temp sensor
adjustment
-20 ¨ 20
0.0
℃
/
℉
Adjust the
temperature sensor
bias
Compress
or
F21
Compressor
delay time
0 -- 10
3
min
F29
Compressor
controlling mode
(temp controlling
mode)
COOL /
HEAT
/C/H
HEAT
-
COOL:
refrigeration mode
HEAT: Heat mode
C/H :Auto mode
Defrosting
F31
Defrost start
temperature
-20 ¨ 80
-2
℃
/
℉
F32
Defrost end
temperature
0 ¨ 100
10
℃
/
℉
F33 Defrost start time
1 ¨ 999
30
min
F34 Max defrost time Off, 1 ¨ 99
10
min
Off
means
no
defrost
F37 Defrost mode
0 - 1
0
-
0:air defrost
1:
4
way
valve
defrost
Water
Pump
F40
Water
Pump
Select
0 ¨ 1
1
-
0: water pump is
not enable
1: water pump is
enable
F41
Water
pump
starts time before
compressor starts
1 ¨ 10
3
min