Heat pump runs
but does not heat
Verify cold air is blowing out the top of the heat pump. If the heat
pump has just been installed or if the pool water has been allowed
to cool significantly, it is necessary to run the heat pump
continually, it is necessary to run the heat pump continually for
24-48 hours. If the heat pump has been in operation for some
time, increase the circulating pump time, or switch the control
board to Maintain Heat function. If heating a spa, verify no air
intake stand pipes are open. If heat pump still does not heat, call
for service.
Heat
pump
leaking water
Possible heat exchanger or plumbing leak. Turn the heat pump
off, then turn circulating pump off for at least one hour to see if the
water leak stops. If the water leak stops. Normal condensation is
occurring. If the water leak continues, after the heat pump is shut
off for at least one hour, call for service.