background image

1

Kit (P/N 580003) Contents

Deck Jet Body — (Qty 4)

Nozzle Kit (P/N 590041) — (Qty 4)

Deck Jet Cover (P/N 590042) — (Qty 4)

Note:

  Each kit contains parts for four (4) MagicStream Deck Jet II units.

Technical support

590043 

( Rev A) 2/1/2008

 

WARNING  — FOR YOUR SAFETY: This product must be installed and serviced by

a professional pool/spa service technician. The procedures in this
manual must be followed exactly. Improper installation and/or
operation will void the warranty.

This document gives instructions for installing the Pentair
MagicStream Deck Jet II. Read through the instructions completely
before starting the procedure..

Sanford, North Carolina 

(8 A.M. to 5 P.M. -  ET)

Moorpark, California 

(8 A.M. to 5 P.M. - PT)

Phone:  (800) 831-7133

Fax:  (800) 284-4151

Web sites: 

 

www.pentairpool.com - www.staritepool.com

MagicStream

TM

 Deck Jet II

Installation Instructions

Содержание Deck Jet II MagicStream

Страница 1: ...pa service technician The procedures in this manual must be followed exactly Improper installation and or operation will void the warranty This document gives instructions for installing the Pentair MagicStream Deck Jet II Read through the instructions completely before starting the procedure Sanford North Carolina 8 A M to 5 P M ET Moorpark California 8 A M to 5 P M PT Phone 800 831 7133 Fax 800 ...

Страница 2: ...g Pentair recommends placing a gravel layer beneath the Deck Jet PentairrecommendsthateachDeckJetbefittedwitha ballvalvetoallowflowcontrolforeachnozzle Forinstallationsinvolvingmultiplenozzles werecommendinstallinga3 wayvalveonthemainlinenearthe pumpforoveralladjustment The Deck Jet is designed for a maximum flow rate of 5GPM at 11 ft of head See table below 2 Cup Swivel nozzle Drain holes Drain c...

Страница 3: ...ivelbaseintotheDeckJetbody Figure2 Byhand pushtheswivelnozzleuntilitsnapsontotheswivelbase Figure3 Operation Startthepumpandadjusttheappropriatevalvesasnecessarytocreatethedesiredwatereffect Ifthestreamofwaterisdisrupted removetheDeckJetCover JetandJetSwivelBase Checktoseeif thereisanydebrisblockingtheJet Towinterize removetheJetandJetSwivelBase Blowthelinesclearwithair andinstalla1 2 threaded plu...

Страница 4: ...ademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Teflon is a registered trademark of E I Du Pont De Nemours and Company Corporation Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Po...

Отзывы: