Rise Digital Bath
installation instuctions
page 10
The Digital processors are supplied
factory set with the flow rate at either
‘NORMAL HP’ or ‘NORMAL GRAVITY’
mode depending on which bath
system has been ordered.
STANDARD PROCESSORS ON BALANCED
HP SYSTEMS:
Standard processors fitted to balanced high pressure systems may
be set to ‘NORMAL HP’ or for water economy ‘ECO’ modes.
N.B. We recommend the processor is set to ‘NORMAL HP’ mode.
STANDARD PROCESSORS ON COMBINATION BOILER SYSTEMS:
For Standard Digital processors installed on combi boiler systems, for
optimum performance we recommend setting the flow rate to the
‘COMBI’ mode.
16
N.B. The ‘ECO’ flow rate mode should not be selected for bath systems
fitted to combination boilers.
PUMPED PROCESSORS:
Pumped processors fitted to gravity systems may be set to ‘NORMAL
GRAVITY’ or for water economy ‘ECO’ flow rate modes.
N.B. We recommend the processor is set to ‘NORMAL GRAVITY’ mode.
WHEN MAKING ANY ADJUSTMENT TO THE PROCESSOR SETTINGS
THE POWER MUST BE ISOLATED.
!
Run the bath at maximum temperature
(factory pre set to 45
0
C). If required,
maximum temperature adjustment can be
made with a flat bladed screwdriver using
the ‘MAX’ TEMP ADJUSTMENT’ control as
indicated. When the temperature has been set
to the desired position carefully replace the
Digital processor lid and secure the fixing hand tight only.
17
Site conditions can affect temperature settings, installer to adjust as required.
ALL COPPER PIPE WORK MUST BE CROSS-BONDED AND CONNECTED TO A
RELIABLE EARTHING POINT.
!