AQUA Sauna Heater
E002B-23-10-12 9
(1)
、
Temp sensor frame (Fig 6)
(Fig6)
(2)
、
Temp sensor instruction (chart 6)
Chart 7
No.
Parts
Description
1
Circuit board
Circuit board
2
Bracket
Bracket
3
Cover
Protects the electronics
4
Heat resistance
Detects temperature
5
High Temp cut of switch
When temperature in sauna room exceed 120
o
C or 248
o
F
Chapter Three: Installation
1. Important
Prior to installing sauna heater, please refer to Installation handbook and check it as following points:
Is the output power and type of the heater suitable for the Sauna Room? See parameter table 1.
(Technical parameter).
Is the supply voltage suitable for the rated voltage of
sauna heater.
The location of the heater fulfils the minimum requirements concerning the distances given in Fig 7
and chart 8
.and allow for safety and convenience.
Choose the cable wire according to table 1, note for the cable to the heater you will need high
temperature resistant sillicon rubber cable wire.
Do not install more than one heater in a sauna room unless twin-heater installations. (Warning: there
must be 400 mm between two heaters when install two).