Aqua ZL 10.5 Скачать руководство пользователя страница 14

AQUA                                                                                                                                                                  Sauna Heater 

    14                                                                                                                                                                                              E002B-23-10-12 

   

 

9.  Insulation   

The door, ceiling and walls of sauna room must be insulated. When one square meter (m

2

) of uninsulated 

surface choosing the heater input (refer to table 1), take following as example: 1 cubic volume increases to 

approximately 1.3m

3. 

Make

 

sure  that  moisture-protection  is  appropriate  in  sauna  room.    Purpose  of  this  is  to  prevent 

spreading moisture to the other rooms or wall structure .    Moisture-protection must be placed between panel 

and heating insulation. 

Moisture and thermal protection should be installed from outside to inside, such as: 

Recommend  that  the  MIN  thickness  of  the  thermal  insulation  in  the  walls  is  25mm  and  in  the  ceiling 

50mm. 

 

10.  Air ventilation of sauna room   

 

  Mix the cold air with hot air to relieve mugginess when bathing. 

 

  Draw the fresh air around the heater to ventilate the sauna room. 

 

  Move the heater air to the farthest part of sauna room considering air ventilation of sauna room, the 

inlet and outlet vent should be installed.   

The  inlet  vent  may  be  installed  on  the  wall  below  the  heater.  (fig  15a).when  using  mechanical 

ventilation ,inlet vent is placed 50cm above the heater (fig 15b) or on the ceiling above the heater (fig 15c).the 

heavy cold air that blown into sauna room is mixed with the light hot air from the heater ,bringing fresh air for 

bathers. The recommended inlet should have a diameter of 5

10cm. 

The outlet vent should be placed diagonally opposite to the inlet. It is advised the outlet vent is placed 

under the platform in sauna room as far as possible from the inlet vent. It can be installed near the floor, or lead 

outside through a pipe from the floor going to a vent to the sauna ceiling, or under the door (to the wash room). 

In  this  case,  the  sill  slot  must  be  at  least  5cm  and  it  is  recommended  there  is  mechanical  ventilation  in 

washroom the size of the outlet should be twice of the inlet.   

 

Warning:

   

1.  Do not power on when making electrical installation.   
2.  Do not hang clothes to dry in the heater, for this may cause a risk of fire. 
3.  Do not bake food in heater.   
4.  Keep away from the heater. When it is hot, the outer surface of the heater may burn your 

skin. 

 
 
 

Содержание ZL 10.5

Страница 1: ......

Страница 2: ...e installed by competent person This equipment must be connected to an all pole isolator of the correct rating Disconnect the power supply before exposing electrical connections The sauna heater shoul...

Страница 3: ...inal2 5 1 5 40 50 ZL10 5 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 ZL12 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 Z...

Страница 4: ...erature Size mm Model L W H OC S 0 110 32 230 120 248 76 42 27 4 Circuit Diagram for sauna heater and control Box i Sauna heater circuit diagram Fig 1 HEATING ELEMENT OCS090B 0CS170B Fig 1 a HEATING E...

Страница 5: ...ax Output Power 12kw Max Output Power 12kw Light Ter m i nal 2 W W V V U U N N L N F N L3 L2 L1 N Ter m i nal 1 Ter m i nal 2 L3 L3 L2 L2 L1 L1 N N 1 2 3 RT 4 HI TEMP CUT OFF MANUAL RESET DOOR RED Pow...

Страница 6: ...No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect the power supply 5 Power entry The rou...

Страница 7: ...be on 12 Wait LED When this LED is on the count down timer is on 13 Sauna room Door interlock indicator LED When this LED is on the door has been opened since your count down timer has been set and so...

Страница 8: ...ten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater light and fan and fasten wires 5 Control cable entry The entry of...

Страница 9: ...it as following points Is the output power and type of the heater suitable for the Sauna Room See parameter table 1 Technical parameter Is the supply voltage suitable for the rated voltage of sauna h...

Страница 10: ...ical connection can cause fire or electric shock Refer to fig 1a or fig 1b Electrical connection chart and fig 2 Fig 7 Chart 8 Safety distance Safety distance A min A max B min C min D min E max Model...

Страница 11: ...talled at a height of approximately 1200mm for ease of use Installation method drill a 40mm hole on wall for the wires You can mount the panel by either drilling two holes 118mm apart for the screws o...

Страница 12: ...1 5 Sauna heater Control box controller light fan and temperature sensor connection drawing Fig10A Fig 10B Fig 10C 6 Door interlock install the switch following the manufacturers instructions and conn...

Страница 13: ...he heater Do not use ordinary stones which may emit harmful substances easily break and do not possess good heating capacity Wash the stones to clear the dust before putting them into the heater Stone...

Страница 14: ...vent should be installed The inlet vent may be installed on the wall below the heater fig 15a when using mechanical ventilation inlet vent is placed 50cm above the heater fig 15b or on the ceiling ab...

Страница 15: ...first use the elements and stones may smoke slightly and give off a smell please ensure the sauna cabin is well ventilated Connect to power supply press key temp and time windows will display data LED...

Страница 16: ...e desired setting is reached press the window will stop flashing You can adjust from the time from 10 minutes to 8 hours Note the controller has a memory function if the power supply is not cut off th...

Страница 17: ...fore the timer setting can be made once the timer begins if the door is opened it will cancel the countdown and won t operate until reset Chapter Five Trouble shooting Guide Please Note that we recomm...

Страница 18: ...t circuit in the temperature sensor or the temperature is higher than 115 or 239 check the connection cable or change sensor 3 Change controller Chapter Six Maintenance We recommend that you inspect t...

Страница 19: ...AQUA Sauna Heater E002B 23 10 12 19 For warranty claims and after sales service please contact your local dealer...

Отзывы: