AQUA Sauna Heater
E002B-23-10-12 17
•
To adjust temperature
:
if you press
“
”
once after you finish setting the time or otherwise twice the
temperature window will flash, enter the required temperature by pressing
“
”
or
“
”
to adjust -
every press will increase or reduce 1
℃
or 2
℉
.you can adjust from 50
℃
-110
℃(
122
℉
-230
℉)
once
the required temperature has been set press
“
”
key the window will stop flashing.
3. Door Interlock
When used in commercial situations such as public buildings where the countdown timer is set to come on
in advance the door interlock switch must be connected as described in Fig 2
–
before the timer is set to
come on in advance the sauna room must be checked by the responsible person to ensure there is no
hazard such as combustible material left over the sauna stove or in the sauna
–
then the sauna cabin door
must be closed before the timer setting can be made
–
once the timer begins if the
door is opened it will cancel the countdown and won
’
t operate until reset.
Chapter Five: Trouble shooting Guide
Please Note that we recommend a suitably qualified person carries out all repairs.
Trouble description
Cause
Solutions
There is no display on
the control panel
when the on/off
switch is pressed
There is a problem with;
1.power supply
2.circuit board transformer
3.fuse
1. Check the power supply. If the power
supply indicator LED L1 (red) is on,
check the wire
2. Change the controller
The controller is on
but the sauna heater
doesn
’
t work
1. The sauna heater hasn
’
t
been connected
2. There is a problem with
the controller
1. Check the connection, refer to
(Fig 2
and Fig 10)
2. Change the controller
OverHeat LED is on
1. The temperature sensor
hasn
’
t been connected
correctly
2. The high temperature cut
off switch is turned off
1. Check the connection to temperature
sensor
2. Check if the high temperature cut off
switch is turned off, if yes ,reset by
hand [page 12]