Aqua ZL 10.5 Скачать руководство пользователя страница 1

 

Содержание ZL 10.5

Страница 1: ......

Страница 2: ...e installed by competent person This equipment must be connected to an all pole isolator of the correct rating Disconnect the power supply before exposing electrical connections The sauna heater shoul...

Страница 3: ...inal2 5 1 5 40 50 ZL10 5 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 ZL12 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 Z...

Страница 4: ...erature Size mm Model L W H OC S 0 110 32 230 120 248 76 42 27 4 Circuit Diagram for sauna heater and control Box i Sauna heater circuit diagram Fig 1 HEATING ELEMENT OCS090B 0CS170B Fig 1 a HEATING E...

Страница 5: ...ax Output Power 12kw Max Output Power 12kw Light Ter m i nal 2 W W V V U U N N L N F N L3 L2 L1 N Ter m i nal 1 Ter m i nal 2 L3 L3 L2 L2 L1 L1 N N 1 2 3 RT 4 HI TEMP CUT OFF MANUAL RESET DOOR RED Pow...

Страница 6: ...No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect the power supply 5 Power entry The rou...

Страница 7: ...be on 12 Wait LED When this LED is on the count down timer is on 13 Sauna room Door interlock indicator LED When this LED is on the door has been opened since your count down timer has been set and so...

Страница 8: ...ten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater light and fan and fasten wires 5 Control cable entry The entry of...

Страница 9: ...it as following points Is the output power and type of the heater suitable for the Sauna Room See parameter table 1 Technical parameter Is the supply voltage suitable for the rated voltage of sauna h...

Страница 10: ...ical connection can cause fire or electric shock Refer to fig 1a or fig 1b Electrical connection chart and fig 2 Fig 7 Chart 8 Safety distance Safety distance A min A max B min C min D min E max Model...

Страница 11: ...talled at a height of approximately 1200mm for ease of use Installation method drill a 40mm hole on wall for the wires You can mount the panel by either drilling two holes 118mm apart for the screws o...

Страница 12: ...1 5 Sauna heater Control box controller light fan and temperature sensor connection drawing Fig10A Fig 10B Fig 10C 6 Door interlock install the switch following the manufacturers instructions and conn...

Страница 13: ...he heater Do not use ordinary stones which may emit harmful substances easily break and do not possess good heating capacity Wash the stones to clear the dust before putting them into the heater Stone...

Страница 14: ...vent should be installed The inlet vent may be installed on the wall below the heater fig 15a when using mechanical ventilation inlet vent is placed 50cm above the heater fig 15b or on the ceiling ab...

Страница 15: ...first use the elements and stones may smoke slightly and give off a smell please ensure the sauna cabin is well ventilated Connect to power supply press key temp and time windows will display data LED...

Страница 16: ...e desired setting is reached press the window will stop flashing You can adjust from the time from 10 minutes to 8 hours Note the controller has a memory function if the power supply is not cut off th...

Страница 17: ...fore the timer setting can be made once the timer begins if the door is opened it will cancel the countdown and won t operate until reset Chapter Five Trouble shooting Guide Please Note that we recomm...

Страница 18: ...t circuit in the temperature sensor or the temperature is higher than 115 or 239 check the connection cable or change sensor 3 Change controller Chapter Six Maintenance We recommend that you inspect t...

Страница 19: ...AQUA Sauna Heater E002B 23 10 12 19 For warranty claims and after sales service please contact your local dealer...

Отзывы: