Speed adjustable peristaltic pump

 

OPERATION OF THE SWITCH 

 

Placed on the lower part of the pump, the switch has 3 positions: 
 

I:  the pump is active (ON) 

  The led is flashing green with a frequency proportional to the speed set on the potentiometer. 

O: the pump is in stand-by (OFF) 

  Led is fixed red. 

II: the pump is in priming mode (MOM) 

  Led is fixed orange, the pump works for 60 seconds at the maximum speed. If the button is pressed again 

before the 60 seconds, the pump goes in stand-by or in normal operation, depending on the position of the 
switch. 

 

LEVEL ALARM (only for the model with level probe) 

A level probe can be connected to the pump to signal the end of the product, which is indicated by the pump in the 
following way: 

 

Acoustic signal through the buzzer (if installed on the pump), with a frequency of 1 second on and 1 second off; 

 

Red led flashing with the same frequency of the buzzer. 

The inlet has a recognition filter both upwards and downwards of 3 seconds for discriminating false contacts and not 
desired level alarm signals. 
During the level alarm, the pump continues rotating with the set speed. 
To exit from this condition, the chemical product to be dosed must be restored. 
 

 

 

In priming mode, the level alarm is not indicated. 

 

MOTOR ALARM 

In case an excessive absorption of the motor occur due to malfunctions, the pump carries out three attempts of activation 
of the motor, after which the alarm is triggered and signalled by the pump in the following way: 

 

Acoustic signal through the buzzer (if installed on the pump), with a frequency of 1 second on and 1 second off; 

 

Red led flashing with the same frequency of the buzzer. 

During the motor alarm, the pump clearly stops. 
To exit from this condition, switch off and on the pump by using its switch or by acting on the power supply. 

 

SWITCH ALARM 

If the switch is left on the OFF position, after 10 minutes the switch alarm is activated and signalled by the pump in the 
following way: 

 

Acoustic signal through the buzzer (if installed on the pump), with a frequency of 2 seconds on and 2 seconds off; 

 

Red led flashing with the same frequency of the buzzer. 

During the motor alarm, the pump clearly stops. 
To exit from this condition, switch off and on the pump by using its switch or by acting on the power supply. 

 

MAINTENANCE (see fig. 3)

 

 

Periodically verify the level of the tank containing the chemical product to be dosed, in order to avoid the pump running 
in vain. 

 

Verify the foot strainer and clean it periodically from any residuals of crystallised product or accumulated dirt. 

 

Ensure there are no impurities in the suction and delivery tubes, because they may damage the peristaltic tube and, at 
the same time, cause anomalies in the capacity.  

 

Periodically verify the operation of the pump and the status of the peristaltic tube, especially for very aggressive 
chemical products. 

PROVIDED KIT OF ACCESSORIES 

Pumps for detergent 

 

PVC suction and delivery tubes (4 m.) 

 

Foot strainer 

 

Tank inlet fitting  

 
Pumps for sparkling aid 

 

PVC suction tube (2 m.) 

 

PE delivery tube (4 m.) 

 

Foot strainer 

 

Steel check valve with viton® o-ring 

 

Tube holder for the check valve 

 

Note on environmental protection 

 

After the implementation of the European Directive 2002/96/EU in the national legal system, the following applies: 
Electrical and electronic devices may not be disposed of with domestic waste. Consumers are obliged by law to return 
electrical  and  electronic  devices at  the  end  of  their service  lives  to  the  public  collecting  points  set  up  for  this  purpose. 
Details  to  this  are  defined  by  the  national  law  of  the  respective  country.  This  symbol  on  the  product,  the  instruction 
manual  or  the  package  indicates  that  the  product  is  subject  to  these  regulations.  By  recycling,  reusing  the  material  or 
other forms of utilizing old devices, you are making an important contribution to protecting our environment. 

 
 

 

 

 

Содержание TEC

Страница 1: ...IC PUMP MANUAL DE SERVICE POMPE PERISTALTIQUE MANUAL DE ISTRUCIONES BOMBA PERISTÁLTICA BEDIENUNGS UND WARTUNGSANLEITUNG РУКОВОДСТВО ПО ПРОГРАММИРОВАНИЮ И УСТАНОВКЕ ПЕРИСТАЛЬТИЧЕСКОГО НАСОСА TEC For other languages please visit http aqua quickris com adsp7000199i new tec ...

Страница 2: ...Accertarsi della presenza di un interruttore differenziale ad alta sensibilità 0 03 A Verificare che i valori di targa della pompa siano compatibili con quelli della rete elettrica Non installare mai la pompa direttamente in parallelo a carichi induttivi es motori Elettrovalvole ma se necessario usare un relè d isolamento All interno della pompa sono presenti due protezioni un varistore ed un fusi...

Страница 3: ... pompa va in allarme interruttore che viene segnalato dalla pompa nel modo seguente Segnalazione acustica tramite il buzzer se presente sulla pompa con frequenza di 2 secondi acceso e 2 secondi spento Led rosso lampeggiante con la stessa frequenza del buzzer Durante l allarme motore la pompa ovviamente è ferma Per uscire da questa condizione di allarme bisogna spegnere e accendere la pompa tramite...

Страница 4: ...the highly sensitive differential switch is present 0 03 A Verify that the rated values of the pump are compatible with those of the mains Never install the pump directly in parallel with inductive loads e g motors solenoid valves if necessary use an isolating relay There are 2 protection devices inside the pump a varistor and a fuse HYDRAULIC INSTALLATION the suction tube must be located inside t...

Страница 5: ...LARM If the switch is left on the OFF position after 10 minutes the switch alarm is activated and signalled by the pump in the following way Acoustic signal through the buzzer if installed on the pump with a frequency of 2 seconds on and 2 seconds off Red led flashing with the same frequency of the buzzer During the motor alarm the pump clearly stops To exit from this condition switch off and on t...

Страница 6: ... and complies with the applicable regulations Make sure that the highly sensitive differential switch is present 0 03 A Verify that the rated values of the pump are compatible with those of the mains Never install the pump directly in parallel with inductive loads e g motors solenoid valves if necessary use an isolating relay There are 2 protection devices inside the pump a varistor and a fuse INS...

Страница 7: ...r ou par l alimentation ALARME INTERRUPTEUR Si l interrupteur est laissé dans la position OFF après 10 minutes la pompe se met en alarme interrupteur qui sera signalé par la pompe de la façon suivante Signalisation acoustique avec l avertisseur si présent sur la pompe avec une fréquence de 2 secondes allumé et de 2 secondes éteint Led rouge clignotant avec la même fréquence d avertisseur Pendant l...

Страница 8: ...un interruptor diferencial de alta sensibilidad 0 03 A Compruebe que los valores de placa de la bomba sean compatibles con los de la red eléctrica Nunca instale la bomba directamente en paralelo respecto a cargas inductivas ej motores electroválvulas es necesario usar un relé de aislamiento Dentro de la bomba hay dos protecciones un varistor y un fusible INSTALACIÓN HIDRÁULICA el tubo de aspiració...

Страница 9: ...tor o bien mediante la alimentación ALARMAS DEL INTERRUPTOR Si se deja el interruptor en la posición OFF luego de 10 minutos la bomba entra en alarma del interruptor que es señalizada por la bomba de la siguiente manera Señalización acústica mediante el zumbador si se encuentra en la bomba con frecuencia de 2 segundos encendido y 2 segundos apagado Led rojo intermitente con la misma frecuencia del...

Страница 10: ...pfindlicher Fehlerstromschutzschalter 0 03 A vorhanden ist Überprüfen dass die Daten auf dem Typenschild der Pumpe den Merkmalen des Stromnetzes entsprechen Die Pumpe niemals direkt parallel zu induktiven Belastungen z B Motoren Elektroventilen installieren sondern wenn notwendig ein Isolierungs Relais verwenden Im Pumpeninneren befinden sich zwei Schutzvorrichtungen ein Varistor und eine Sicherun...

Страница 11: ...h 10 Minuten in den Alarm Schalter über und dieser wird wie folgt angezeigt Akustisches Signal über Buzzer wenn bei Pumpe vorhanden im Takt 2 Sekunde eingeschaltet und 2 ausgeschaltet LED Leuchte blinkt rot auf im selben Takt des Buzzers Während der Alarm Motor ist die Pumpe ausgeschaltet Um diese Funktionsweise zu verlassen muss die Pumpe über den Schalter oder über die Versorgung aus und wieder ...

Страница 12: ...рисутствовало устройство полюсного отключения на расстоянии открытия контактов мин 3 мм ВНИМАНИЕ Убедиться что система заземления совершенно исправна и соответствует действующим нормам Убедиться в наличии высокочувствительного дифференциального выключателя 0 03 A Убедиться что значения на табличке насоса совместимы с параметрами сети электропитания Никогда не устанавливать насос непосредственно па...

Страница 13: ...йства если оно установлено на насосе частотой 1 секунда включен и 1 секунда выключен Красный светодиод мигает с той же частотой что и сигнальное устройство Во время работы сигнального устройства насос не работает Для решения этой проблемы необходимо выключить и вновь включить насос СИГНАЛ ВЫКЛЮЧАТЕЛЯ В случае если насос оставлен более 10 минут с выключателем в позиции OFF он подаст сигнал об этом ...

Страница 14: ...co Entfernen des Peristaltikschlauchs Снятие перистальтической трубки Rif Descrizione Ref Description A Led bicolore A Two coloured led B Potenziometro B Potentiometer C Porta rullini C Roll holders D Tubo peristaltico D Peristaltic tube E Raccordo di aspirazione E Suction fitting F Cavo di alimentazione 2x0 75mm2 2 m F Power cable 2x0 75mm2 2 m G Raccordo di mandata G Delivery fitting Réf Descrip...

Страница 15: ...o peristaltico Repositioning the peristaltic tube Repositionnement du tuyau péristaltique Reposicionamiento del tubo peristáltico Erneute Positionierung des Peristaltikschlauchs Установка перистальтической трубки Fig 1 Fig 2 Fig 3 Fig 2 Assembling Disassembling ...

Страница 16: ...06 08 2014 ADSP7000199I Rev 1 5 16 Fig 4 Fig 5 Fig 5 ...

Страница 17: ...06 08 2014 ADSP7000199I Rev 1 5 17 ...

Страница 18: ...06 08 2014 ADSP7000199I Rev 1 5 18 PDP TEC RS 230V PDP TEC 230V Assorbimento Watt Assorbimento Watt 8 4 ...

Страница 19: ...06 08 2014 ADSP7000199I Rev 1 5 19 For other languages please visit http aqua quickris com adsp7000199i new tec ...

Страница 20: ...06 08 2014 ADSP7000199I Rev 1 5 20 ADSP7000199I Rev 1 5 TEC ITA ING FRA SPA TED RUS ...

Отзывы: