NOTE:

 Before performing any reassembly, it 

is important to inspect all parts, both new and 

those that are being re-used, to ensure that 

every part and component is perfectly clean 

and free of any dust, corrosion, or blemishes.  

Check all o-rings to ensure they are clean and 

supple before dressing with Christo-Lube

®

MCG 111.

15.  When the crown (16) has been unthreaded from the 

inlet  fi tting (19), carefully insert the pin of the seat extraction 

tool into the opposite end of the inlet fi tting and through the 

center of the crown. Gently press the crown out onto a 

padded surface.

16.  Closely examine the crown (16) with the use of a 

magnifi er to check for any scoring, nicks or other damage to 

the  polished sealing surface. If damage is found, discard the 

crown, and do not attempt to reuse. If it is in reusable 

condition, set it aside on a soft surface to prevent damage to 

the sealing edge.

17. Remove the o-rings from the crown and the inlet fi tting.

THIS ENDS DISASSEMBLY

Before starting reassembly, perform parts 

cleaning and lubrication in accordance with 

Procedure A: Cleaning and Lubricating

 (p. 14).

Procedure A: Cleaning and Lubricating

Procedure A: Cleaning and Lubricating

REASSEMBLY PROCEDURE

1.  If you removed the exhaust valve (3) during disassembly  

install the exhaust valve into the exhalation box (2) by feeding 

the stem through the hole in the box (from the inside) and pull 

gently on the stem using needle nose pliers until the barb has 

passed through and is securely seated against the opposite 

side of the box.  

If you are installing a new valve, carefully snip off the 

excess material  of the stem with a small pair of scissors, 

leaving 5mm.

2. Install the o-ring (17) onto the crown (16) and o-ring (18) 

onto the inlet fi tting (19).

3.  Carefully insert the threaded end of the crown into the 

hose connection of the inlet fi tting. Gently press it in further 

with the blunt end of the seat extraction tool until it stops. 

Содержание MISTRAL SECOND STAGE

Страница 1: ...Authorized Technician TECHNICAL MAINTENANCE MANUAL MISTRAL SECOND STAGE...

Страница 2: ...Y PROCEDURE 6 FINAL TESTING PROCEDURES 10 Second Stage Opening Effort Test 10 Table 1 Troubleshooting Guide 11 Table 2 List of Tools and Service Kits 12 Table 3 Recommended Cleaners and Lubricants 13...

Страница 3: ...the hose crimps If a regulator fails item 1 2 3 or 4 the entire regulator should be overhauled If a regulator fails 4 5 6 or 7 it will be up to the technician s discretion whether or not a full overha...

Страница 4: ...the surface is clean and unscratched It should be exible and have a clean edge If it is in good condition it is not necessary to replace it If there are any signs of deterioration it should be replac...

Страница 5: ...condition of the lever 10 and the spring 13 to ensure it is not bent corroded or other wise damaged If any signs of damage are found discard the part and do not reuse 12 Place the handle of the seat e...

Страница 6: ...amage to the sealing edge 17 Remove the o rings from the crown and the inlet tting THIS ENDS DISASSEMBLY Before starting reassembly perform parts cleaning and lubrication in accordance with Procedure...

Страница 7: ...er the sealing edge of the crown 7 Place the poppet bearing 12 over the pin of the extraction tool with the square feature facing up Guide the pin of the tool into the open end of the valve body 11 an...

Страница 8: ...ew in the inlet tting snug by hand while pressing the lever down 14 Using a torque wrench and a 3 4 19mm crows foot torque the inlet tting 19 to 85 in lbs 15 Fit new lubricated o rings to the MP hose...

Страница 9: ...ever touching the tool there should be no leaks Once the adjustment is completed turn off the air supply and purge the regulator 19 Install the sealing ring 4 onto the diaphragm 5 and place the assemb...

Страница 10: ...b shut and then slowly reopen while watching both the magnahelic gauge and the medium pressure gauge a If the opening effort is too low disassemble the second stage to give access to the lever disasse...

Страница 11: ...pring 12 is damaged 7 Replace the spring Breathing effort is too high 1 MP is too high 1 Readjust the lever and the crown 2 The lever 9 is adjusted too low 2 Readjust the lever and the crown 3 The MP...

Страница 12: ...ing bands 944022 O ring removal and installation N A 3mm Allen Keys Assemble disassemble casing N A Cleaning inside of corrugated hoses N A Removing panduit clamps 900016 Service Kit MISTRAL Crown and...

Страница 13: ...r reusable stainless steel and brass parts Household grade Liquid dishwashing detergent diluted with warm water Degreaser for brass and stainless steel parts general cleaning solution for plastic and...

Страница 14: ...e stubborn deposits household white distilled vinegar acetic acid in an ultrasonic cleaner will work well DO NOT place plastic rubber silicone or anodized aluminum parts in vinegar 3 Remove parts from...

Страница 15: ...CRIPTION KEY ITEM TORQUE 104106 Inlet tting 19 85 in lbs Table 5 Checking Speci cations TEST CONDITION SPECIFICATIONS Leak Test Inlet 2500 3000 100 psig No leaks allowed Opening Effort Inlet 2500 3000...

Страница 16: ...16 Maintenance Notes...

Страница 17: ...900016 Overhaul Parts Kit Entire Mistral 1 125929 Screw caphead 2 125935 Exhalation box 3 129174 Exhaust valve 4 124509 Sealing ring 5 125705 Diaphragm 6 125937 Inhalation box 7 7 7 125928 Locknut 8 8...

Страница 18: ...Authorized Technician TECHNICAL MAINTENANCE MANUAL MISTRAL SECOND STAGE Aqua Lung America 2340 Cousteau Court Vista CA 92081 760 597 5000 www aqualung com Rev 2 2006 Aqua Lung USA Aqua Lung USA...

Отзывы: