Table 4: Torque Specifi cations
PART #
DESCRIPTION / KEY ITEM #
TORQUE
104106
Inlet fi tting (19)
85 in/lbs
Table 5: Checking Specifi cations
TEST
CONDITION
SPECIFICATIONS
Leak Test
Inlet 2500 - 3000 (± 100 psig)
No leaks allowed
Opening Effort
Inlet 2500 - 3000 (± 100 psig)
MP 135 ± 5 psi
+ 1.0 – 1.7 in. H²O
Flow Effort
MP 135 ± 5 psi at 15 SCFM
+ 6 in. /H²O (Maximum)