![Aqua Lung G3000SS Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/aqua-lung/g3000ss/g3000ss_operation-and-maintenance-manual_2958530069.webp)
APPENDIX I
SHIELD, WELDING ASSEMBLY (P/N 400102)
INSTALLATION INSTRUCTIONS
This procedure is to be performed only by personnel who have received appropriate training.
If you do not completely understand all of the procedure, contact Aqua Lung to speak directly
with a Technical Advisor before proceeding any further.
Step 1: Use a Phillips # 3 screwdriver
to remove three retainer port screws
(11) from top of helmet retainer port
(12).
Step 2: Install shield welding spring
(78) and retainer port screw (11).
Tighten to 45 in.lbs (5 Nm).
Step 3: Line up welding lens assembly.
Step 4: Secure and tighten left and
right hinge block mounting screws
(79) to 45 in.lbs (5 Nm).
Step 5: Secure and tighten left
and right hinge screws (80) to 45
in.lbs (5 Nm).
Step 6: Confirm welding shield
opens and closes correctly.
KIT CONTENTS
Part #
Item Description
Qty per Kit
400087
Body, Welding Shell (Shield)
1
400088
Lens, Welding
1
400089
Bracket, Lens Holding
2
400090
Gasket, Welding Lens
1
400035
Screw, Hex, Manifold
2
400092
Hinge Block, Welding Lens
2
400093
Screw, Hinge Block Mounting
2
400094
Screw, Hinge
2
400095
Shield, Welding Spring
1
400015
Screw, Retainer Port
1
Step-by-Step Assembly Instructions