Step 35: Tighten short hex screw
(39) onto the bottom of helmet
using a 3/16" hex key to 80 in.lbs
(9 Nm).
Step 36: Tighten short hex screw
(39) onto the top of helmet using a
3/16" hex key to 80 in.lbs (9 Nm).
Step 37: Manifold installed.
Step 38: Line up neck retainer (21)
with the hinge and insert the neck
retainer bolt (23).
Step 39: Put the neck retainer
nut (22) on the neck retainer
bolt (23).
Step 40: Use a 3/16" hex key to
hold the bolt (23) and 7/16" nut
driver to hold the nut (22). Tighten
until the nut touches the hinge.
Adjust as required.
Note:
Ensure that neck retainer
moves freely.
Step 32: Line up assembled
manifold body (45) with the
manifold insert (40) and holes.
Step 33: Use longer manifold
hex screws (10) on left side and
short manifold hex screws (39)
on right side.
Step 34: Tighten the longer
manifold hex screws (10)
onto inner airway bracket
using a 3/16" hex key to 80
in.lbs (9 Nm).
Long
Screw
Short
Screw