NECK RETAINER AND LOCKING SYSTEM
Step 1: Breakdown of locking
system parts.
Note: There are left and right
latch catch assemblies
Step 2: Insert left latch (2) or right
latch (3) into corresponding latch
base left (6) or latch base right (7).
Step 3: Latch inserted in latch
base.
Step 4: Fit latch spring (8) over shaft
of left latch (2) or right latch (3).
Step 5: Fit latch spring washer (9)
onto manifold hex screw (10).
Step 6: Insert manifold hex screw
(10) and washer (9) into shaft of
left latch (2) or right latch (3).
Step 8: Fit assembled latch base
left (6) or latch base right (7) onto
correct side of helmet shell (1).
Step 9: Fit latch spring washer
(5) onto latch screw (4).
Step 7: Tighten manifold hex
screw (10) using a 3/16" hex key
to 80 in.lbs (9 Nm).
37