DAILY CHECKLIST (continued)
ACTION
PROCEDURE
INITIALS
ATTACH THE UMBILICAL
(to be completed by tender)
• Confirm the check valve is properly functioning by
orally checking it (suck on valve to confirm seal).
• Blow air through the umbilical to remove any debris,
and attach the umbilical into the umbilical adapter
located on the check valve.
CHECK THE SECOND
STAGE REGULATOR
(must be completed by diver/tender)
• Slowly depress the purge button to full extent and
confirm a sufficient audible flow of gas.
NOTE:
If the regulator free flows, or if after
fully depressing the purge button there is a
weak flow of gas, the regulator needs to be
adjusted or the low pressure valve should be
replaced or serviced by a trained technician.
CONFIRM FUNCTION OF
COMMUNICATIONS
(to be completed by diver)
• Check all communications to confirm correct
functioning.
CHECK DRY-SUIT
INFLATION HOSE
(must be completed by tender).
• If fitted, confirm the dry suit inflation valve and
exhaust valve are functioning properly.
CHECK HELMET FOR
LEAKS
• Apply soap and water to ALL gas fittings and
connections (including the EGS) to check for
leaks on the helmet.
FINAL CHECK
(to be completed by tender)
• Check to ensure the neck retainer is in the correct
position and properly locked.
• Ensure the diver's safety harness is in good
condition.
• Ensure the umbilical strain is released.
• Ensure the EGS hose quick disconnect is in good
condition and is functioning properly.
• Ensure diver has boots, gloves, knife and other
accessories.
To Diver / Tender: Note comment on the space provided below. Be sure to log maintenance in
the applicable maintenance log.
Comments:
Signature:
Date:
14
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual