V. HELMET TECHNICAL INFORMATION
AUTHORIZED TECHNICIANS
The technical procedures in this manual are to be performed only by personnel who have
received factory authorized training through an Aqua Lung Service & Repair Seminar.
TECHNICAL SECTION
FACTORY PRESCRIBED PROCEDURES
This manual provides factory prescribed procedures for the correct service and repair of the G3000SS
diving helmet. It is strongly recommended that all repairs are completed in accordance with this manual.
If you do not completely understand all of the procedures outlined in this manual, contact Aqua Lung to
speak directly with a technical advisor before proceeding any further.
SCHEDULED SERVICE
1. The G3000SS Diving Helmet is subject to annual service regardless of usage.
2. The
Annual Inspection and Maintenance Checklist
must be followed for annual service.
See Checklist
6
for details of annual service.
3. The annual service kit (P/N 400180) contains all parts that are replaced annually
(See Appendix R)
for details of this kit.
LUBRICATION
A oxygen compatible lubricant must be used when diving with 100% oxygen or gas containing oxygen
percentages greater than 40%. All helmet components requiring lubrication are lubricated with Christo
Lube MCG-111 during assembly.
All o-rings must be lubricated prior to assembly.
CAUTION: DO NOT lubricate diaphragms or one-way valves. Lubrication attracts dirt
and debris, this may cause the item to malfunction.
23