•
Detach the expansion tank water drain
pipe from the pipe guide connected to
the mounting bracket of the radiators
and remove the pipe retainer clip se-
curing the drain pipe to the cable of the
demand sensor.
•
Remove the cable tie fastening the ca-
ble of the demand sensor to the drain
pipe of the expansion tank.
•
Move the metal clips along the pipe
and disconnect the cooling system
pipe from the pump and the connector
pipe leading to the thermostat valve.
•
Move the metal clip along the pipe and
disconnect the cooling system pipe
from the radiator.
Cooling system
RSV4 1100 Factory
COOL SYS - 462
Содержание RSV4 1100 Factory 2021
Страница 1: ...MANUALE STAZIONE DI SERVIZIO 2Q000479 RSV4 1100 Factory ...
Страница 6: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Страница 12: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 53: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Страница 61: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 105: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 184: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 213: ...INDEX OF TOPICS ENGINE ENG ...
Страница 330: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Страница 334: ... Ease out the pump taking particular care not to damage the pump Injection Power supply RSV4 1100 Factory P SUPP 334 ...
Страница 341: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 383: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 428: ...Chassis RSV4 1100 Factory CHAS 428 ...
Страница 429: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 452: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Страница 464: ...INDEX OF TOPICS BODYWORK BODYW ...