Working Standard
User’s Guide
www.appliedp.com
WS-UGFW619-EN
65
Load Point Parameters
shown in Table of Parameters of selected load point:
DATE
test date
TIME
test time
MCURR
current (3x)
MVOLT
voltage (3x)
MPHI
current phase angle (3x)
MPHU
voltage phase angle (3x)
MDFI
current distortion (3x)
MDFU
voltage distortion (3x)
FREQ
frequency
MPOWER
active power (3x)
MQPOWER
reactive power (3x)
MSPOWER
apparent power (3x)
MPOWFACT
power factor (3x)
MENERGY
active energy (3x)
MQENERGY
reactive energy (3x)
MSENERGY
apparent energy (3x)
MSPOWERSUM
sum of apparent powers
MPOWERSUM
sum of active powers
MQPOWERSUM
sum of reactive powers
MSENERGYSUM
sum of apparent energies
MENERGYSUM
sum of active energies
MQENERGYSUM
sum of reactive energies
CONTYPE
connection type
CTRATIO21
Transformation ratio of
currents I2 / I1
CTRATIO31
Transformation ratio of
currents I3 / I1
CTPHASE21
Phase Error I2 - I1
CTPHASE31
Phase Error I3 - I1
VTRATIO21
Transformation ratio of
voltages U2 / U1
VTRATIO31
Transformation ratio of
voltages U3 / U1
VTPHASE21
Phase Error U2 - U1
VTPHASE31
Phase Error U3 - U1
CTRATIOERR21
Ratio Error I2 / I1
CTRATIOERR31
Ratio Error I3 / I1
VTRATIOERR21
Ratio Error U2 / U1
VTRATIOERR31
Ratio Error U3 / U1
MVOLTA
Voltage Ua (3x)
MVOLTB
Voltage Ub (3x)
MPHUA
Phase Angle of Ua (3x)
MPHUB
Phase Angle of Ub (3x)
CTRATIOBA
Transformation ratio of
currents Ib / Ia (3x)
CTPHASEBA
Phase Error Ib
– Ia (3x)
CTRATERRBA
Ratio Error Ib / Ia (3x)
MDFIXActive;
MDFIXReactive;
MDFIXApparent
MD power register
actualized in fixed time
window
MDSlidActive;
MDSlidReactive;
MDSlidApparent
MD power register
actualized in “slided” time
window
MDPeriod
Size of time window
(Fix/Slide) of MD test
MDSubPeriods
Number of sub periods of
MD Test
MVOLT12
line voltage between
L1;L2
MVOLT23
line voltage between
L2;L3
MVOLT31
line voltage between
L3;L1
MPHU12
phase shift between line
voltage L12 and L1
MPHU23
phase shift between line
voltage L23 and L2
MPHU31
phase shift between line
voltage L31 and L3
MSINPH
Sinus of phase shift
between current and
voltage (3x)
MACTCURR
Ohmic load of current
component (3x)
MREACTCURR
Reactive component of
current (3x)
MZ
Load impedance (3x)
MPHZ
Phase shift of impedance
load (3x)
MDFUA
Voltage Distortion of Ua
(3x)
MDFUB
Voltage Distortion of Ub
(3x)
VTRATIOBA
Transformation ratio of
voltages Ub / Ua (3x)
VTPHASEBA
Phase Error Ub
– Ua (3x)
VTRATERRBA
Ratio Error Ub / Ua (3x)
MCURRA
Current Ia (3x)
MCURRB
Current Ib (3x)
MPHIA
Phase Angle of Ia (3x)
MPHIB
Phase Angle of Ib (3x)
MDFIA
Current Distortion of Ia
(3x)
MDFIB
Current Distortion of Ib
(3x)