yellow / green earth wire. The socket or switch must be easily accessible with the oven fully installed.
•
If the appliance is to be wired using a standard plug, please ensure it corresponds to the load indicated
on the data plate.
•
The use of adapters, multiple sockets and / or extensions, is not recommended.
Connection:
•
A cable of the correct size and rating must be used: Type HO5RR-F 3 x 1.5mm².
•
Using a screwdriver, open the connector cover at the rear of the appliance.
•
To open, release the two locks located on either side of the connector box as shown in Fig 1.
•
Feed the mains cable through the cable clamp to protect the mains lead cable from disconnection.
•
Connect the wires in accordance with the diagram shown below (Fig 1).
•
Tighten the cable clamp and close the connector cover.
Fig. 1 – Connection to the appliance
Connection to 13A plug
Colour coding:
• The GREEN/YELLOW wire is the EARTH and must be connected to the terminal which is marked with the
letter ‘E’ or ‘PE’, by the earth symbol or coloured GREEN or GREEN/YELLOW.
• The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter ‘N’ or
coloured BLACK.
• The BROWN wire is the LIVE wire and must be connected to the terminal which is marked with the letter ‘L’
or coloured RED.
Содержание UEFM601SS