6
Functions and Features
1. Built-in decoder
z
Digital design, data will not be lost while power fails.
z
With recovery, function while turning on the users can run it as you like.
z
Support 200 presets, 4 preset patrolling scanning routes, each contains 24
presets, and the presets can be separately programmed
z
4 patterns, each can be recorded for 100 different running track, including P/T
or lens’ operation and camera control.
z
Support 4-auto scan.
z
Soft and hard ID setting can be edited on the DIP switch and inner menu.
z
Integrated multi-protocol control: PELCO“P”, PELCO“D”.
z
Support auto leisure function.
z
Support 8 privacy zones setting in maximum.
z
Proportional zoom lens, P/T speed and depth of zoom lens will decrease in
proportion.
2.
Integrated assembling design, built-in P/T
z
6-inch transparent cover, black and non-transparent rotation dome, ensuring
safety monitor.
z
Inside / outside various installment methods.
z
Horizontally controlling speed 0.5º-240º/s.
z
Vertically controlling speed 0.5º-220º/s.
z
360º continuously horizontal rotation, all-direction monitor.
z
Comply with IP 66/CE standard.
z
Built-in surge protection device
3.
Built-in zoom lens, integrated digital color camera of high
sensitivity and Resolution
z
Many high-resolution cameras of various models provided by different
manufacturers can be available.
z
Auto focus, manual priority.
z
Auto iris.
z
Auto shift from C-W/B
43
Fault Analysis
Attention
:
Some operation need to restart dome.
Failures
Possible reason
Resolution
Voltage out or
damaged
exchange
Power line
disconnection
modify
No action and no
image after power
on
Project network fault
eliminate
Wrong video link
modify
Bad video link
eliminate
Successful auto
test but no image
Camera damaged
exchange
Mechanical failure
eliminate
Tilt camera
Put right
Abnormal auto test,
chirping sound,
image display
Power not
exchange
Wrong access control
line
modify
No set address
reset
Successful auto test
but can’t control
Inconsistent baud rate,
protocol
reset
Bad video link
eliminate
Instable image
Power not
exchange
Abnormal self test
restart
Bad control circuit
eliminate
Control operation
unusual
modify
Out of control
Over nodes, low
network quality, over
tran. distance
1, Inspection
terminator
2, Increase the
repeaters