Three-phase four-wire (
△
type) connection, the output voltage range is 0~519V.
B
1 2 3
ON
A
C
G
L1
L2
L3
N
1
2
3
4
1
2
3
4
Output connection
Termination resistor CAN-R, flip Dip Switch 1 of the Master unit to ON position
System Bus Communication Cable
Only support three-phase five-wire input connection
90
Master-slave Mode Operation
Master-slave Mode Operation
PROFESSIONAL INNOVATIVE BRANDING SERVICE
6.2.4 Error List of Master-slave Mode
Information
Instruction
Alarm Code
0x0401
0x0402
0x0404
0x0408
0x0410
0x0420
0x0420
0x0480
0x0500
Mode Not Match
Model Not Match
No Phase B
No Phase C
Master Conflict
CAN No Slave
CAN No Master
Slave Conflict
Slave offline
6.2.5 Function Instruction
Sub-menu
Menu
Output
&
More
Setting
Single Unit
Parallel System
Series System
3-Phase System
Waveform
Measure Setting
Yes
Yes, slavers in sync with the master unit
Yes, slavers in sync with the master unit
Yes, but only the master unit can display
Yes
Yes
Yes
Not Supported
Yes
Yes
Yes
Yes
Yes
Yes
Not Supported
Not Supported
Applies to phase
A only. Phase B
& C will be shifted
120
°
&
240
°.
On Degree
[1]
Soft Start
Off Degree
Coupling
Range
Waveform Preview
Zo Program
Irange
Average
Is Delay
Is Interval
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes, slavers in sync with
the master unit
Yes, slavers in sync with
the master unit
Yes, slavers in sync with the master unit
Yes, slavers in sync with the master unit
Yes, slavers in sync with the master unit
Mode not match
Model not match
No Phase B
No Phase C
More than one mater units in the system
No salver can be found
No Master can be found
More than one slavers have the same number
Slave offline
91
PROFESSIONAL INNOVATIVE BRANDING SERVICE