Mechanical parameters

 Sensor mechanical parameters

Dimensions

:<

 44*33*85mm

L*W*H

Net weight

about 49.7g

The external dimension of the sensor is as follows

 Monitoring terminal mechanical parameters

Dimensions

102*28.5*22mm

L*W*H

Monitoring terminal net weight

about 400g

The external dimension of the monitoring terminal is as

follows

 Adapter power mechanical parameters

Dimensions

124*61*40mm

L*W*H

Adapter power net weight

about 234g

The external dimension of the adapter power is as follows

System integrated power supply mechanical parameters

Dimensions

380*160*50mm

L*W*H

System integrated power supply net weight

about 2500g

The external dimension of the system integrated power supply is as 

follows

 Communication converter mechanical Parameters

Dimensions

:<

 90*28*22mm

L*W*H

Communication converter  net weight

about 20.5g

The external dimension of the communication converter

is as follows

Nut Post

100

120

52

76

87.5

14

14

4

25

IMS Smart Controller

WAN/LAN

P4

P3

P2

P1

POWER

P1-P4 : 1/2-VCC  3-RS485_B  4-RS485_A  5/6-GND  7-C_VTH/HVAL  8-C_ACT/Clean  9-PE(Metal shield)

P1

P2

P4

P3

Red-VTH/HVAL

    

ACT/Clean-Green

ACT

Work/Link

NEXT

SCAN

NEXT

LINK

B

SET

S

SCROLL

T

output port

(24V DC 1/2 line output)

Three-phase power socket

AC100-240V

50/60Hz

port

port

380

160

SW1

P1

P2

P3

P6

P5

P4

P7

P8

P10P

9

P11

P13P

12

P15

P16P

14

P30

P32P

31

P28

P29

P27

P26P

25

P17

P18

P19

P21

P20

P23

P24P

22

DC_24V

PLC

RS485

WAN/LAN

P1-P32 : 1/2-VCC     3-RS485_B     4-RS485_A     5/6-GND     7-C_V

TH

/HV

AL

     8-C_ACT/Clean     9-PE(Metal shield)A

C

Red-V

TH

/HV

AL

     

ACT/Clean-

Green

SW2S

W4

SW3S

W5

SW6S

W10

SW8S

W9

SW7S

W11S

W13

SW12

SW14

SW15

SW16

P1

P17

P18

P2

P4

P3

P20

P19

P7

P8

P6

P5

P23

P24

P22

P21

P29P

30

P32

P31

P27

P28

P26

P25

P9

P10P

12

P11P

15

P16

P14

P13

V/A Display

IMS Power Supply

Link

Work

RX

TX

ACT

TX

RX

50

8-M4 

mounting holes

Содержание AP-YV3303

Страница 1: ...Intelligent Electrostatic Sensor AP YV3303 AP TR The second generation Shanghai Anping Static Technology Co Ltd Intelligent Electrostatic Sensor AP T ...

Страница 2: ...tion distance can be selected by the DIP switch Adjustable Detection distance A closed loop monitoring and elimination system is formed by electrostatic sensing detection equipment electrostatic elimination equipment power supply equipment display equipment and IMS ionization monitoring system to realize automatic and unmanned electrostatic monitoring and elimination Closed loop Static electricity...

Страница 3: ... and elimination system Terminal power Closed loop electrostatic detection monitoring and elimination system The closed loop electrostatic monitoring and elimination system formed by detection equipment elimination equipment power supply equipment display equipment and IMS Ionization Monitoring System can realize real time monitoring data storage and dynamic display under the control of system sof...

Страница 4: ...ltage range and minimum resolution corresponding to each detection distance Specification two Detection gear Distance coding Detection distance Range Resolution Error Zero runout Calibration 1 0 5mm 2000V 1V 10 1V 1 10mm 4000V 2V 2V 2 2 25mm 20000V 10V 10V 3 50mm 20000V 10V 10V 3 4 100mm 20000V 10V 10V 5 150mm 20000V 10V 10V 4 6 200mm 20000V 10V 10V 7 250mm 20000V 10V 10V 5 8 300mm 20000V 10V 10V ...

Страница 5: ...charged objects The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate Do not adjust zero in the static charge state or in the electrostatic detection proces...

Страница 6: ...onverter net weight about 20 5g The external dimension of the communication converter is as follows Nut Post 100 120 52 76 87 5 14 14 4 25 IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shield P1 P2 P4 P3 Red VTH HVAL ACT Clean Green ACT Work Link NEXT SCAN NEXT LINK B SET S SCROLL T output port 24V DC 1 2 line output ...

Страница 7: ... withstand voltage of the resistance should be 20KV the current passing through the protection resistance and the human body should be 5mA and the resistance value should meet the requirements of the following formula In the formula R is the protection resistance the unit is ohm Ω Rd is the resistance of the insulating support the unit is ohm Ω the resistance value is 1013Ω and the withstand volta...

Страница 8: ...al test data chart of standard plate electrode The test is divided into vertical test and horizontal test The schematic diagram 9 of the sensor test device is as follows The vertical test data of the sensor and the standard plate electrode are as follows 10000 50000 5000 10000 10000 5000 0 5000 10000 Standard voltage slopeK 1 Test distance100mm Test distance300mm Test distance500mm The measured vo...

Страница 9: ...e 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 within the horizontal distance range of 200mm X 200mm under the vertical test distance of 300mm for the 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 ...

Страница 10: ...wer supply for comprehensive on line mode These three network ports of the 24V power adapter the monitoring terminal and the electrostatic sensor are both power ports and communication ports which can be used in common Connection to monitoring terminal Connection to PC IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shi...

Страница 11: ...ring software according to the withstand static voltage value of the protected product Note The threshold alarm indicator light is green when the detected static voltage value is within the set electrostatic threshold value while the light is red when it exceeds the set threshold value Use a Phillips screwdriver with a diameter of 3mm to turn the ADDR circular DIP switch to set the device address ...

Страница 12: ...gh vibration area otherwise data errors may occur Please check the power cable or communication cable of the product regularly and replace it immediately if it is damaged Otherwise it will easily cause problems such as leakage of electricity poor communication and abnormal work It may cause failure when the product suffers from mechanical shocks such as drops bumps etc The whole equipment must be ...

Страница 13: ... according to the use environment and static control requirements 5 Product has an odor Component burn out Return to factory for maintenance 6 Please contact the manufacturer or seller if there are other unlisted problems or the problem cannot be solved through the above solutions Trouble shooting 1 Please store the equipment in a dry place away from light and do not put heavy pressure on it when ...

Страница 14: ...nitoring analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...

Отзывы: