background image

Product Operation Technical Tips

Monitor terminal display information

There will inevitably be more or less positive and negative ions in the detection space which will also have a certain impact on the detection results 
due to the existence of cosmic rays, trace radioactive substances in the environment, and the use of various electrical equipment.

Working status: monitor whether the sensor is working normally and alarm output

Equipment Address: Display the address set by the sensor

Detection distance: Display the detection distance set by the electrostatic sensor

Threshold voltage: Displays the set static voltage safety (alarm) threshold

Real-time voltage: display the static voltage value on the surface of the measured object

IMS Smart Controller

P3

P2

WAN/LAN  P1

P4  POWER

P1-P4 : 1/2-VCC  3-RS485_B  4-RS485_A  5/6-GND  7-C_V

TH

/HV

AL

  8-C_ACT/Clean  9-PE(Metal shield)

P1

P2

P4

P3

Red-V

TH

/HV

AL

    

ACT/Clean-Green

ACT

Work/Link

NEXT

SCAN

NEXT

LINK

B

SET

S

SCROLL

T

RJ45 port

2.4G communication antenna

Wireless connection

WAN/LAN

Ethernet connection port

M4 mounting holes

Temperature and humidity detection window

Aim at the LED on the front of the product during operation (the distance should not exceed 1m), first press the unlock key, and then press the 

corresponding function key to set, the red light flashes when the key is pressed.

 The calibration plate should be much larger than the sensor detection window, and the plate and sensor should be well grounded when performing 

zero adjustment.

The calibration plate should be much larger than the sensor detection window, and the sensor should be well grounded when performing calibration.

There should be no obstruction between the sensor and the detected object, otherwise the accuracy of the detection result will be affected.

There should be no electrical equipment that may affect the sensor within the detection distance of the sensor.

The plane of the sensor detection window must be parallel to the surface of the object to be measured to accurately measure charged objects.

The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate.

The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate.

Do not adjust zero in the static charge state or in the electrostatic detection process (Non-electrostatic calibration process); the displayed static value 

will be zero if reset it during static electricity testing.

Influence of temperature and humidity on electrostatic detection:

The lower the temperature, the lower the humidity, the less moisture in the space, the easier the surrounding objects are to be electrified by 

friction, and the greater the interference to electrostatic detection.

The higher the temperature, the higher the humidity, the more moisture in the space, the more active the movement of water molecules, the more
easily the calibration device generates corona or spark discharges, and the greater the impact on the uniform electric field generated by the 
calibration device which will weaken the uniform electric field.

The lower the temperature, the less moisture in the space, the easier the surrounding objects are to be electrified by friction, and the greater the 
impact on electrostatic detection under the same humidity. 

     Therefore, the ambient temperature and humidity during calibration/testing should be clearly marked when doing electrostatic calibration/testing.

LCD

Electrostatic sensor monitoring settings

Temperature and humidity display

Wrok/Link

Network connection

red light flashing, green light always on 

Network disconnection

red light flashing, green light is off

Electrostatic eliminator running time setting

Electrostatic eliminator monitoring settings

ACT

Monitor power-on indication, green light always on

P1→P4

4 ways status indicator light

Red light flashing: Sensor threshold alarm/eliminator high voltage alarm 

Green light always on: Sensor/eliminator power-on indication

Green light flashing: Eliminator cleaning indication

POWER

Monitor power port 

(with RS485 communication)

P1→P4

The working status monitoring and 

power supply port of the eliminator or sensor

Содержание AP-YV3303

Страница 1: ...Intelligent Electrostatic Sensor AP YV3303 AP TR The second generation Shanghai Anping Static Technology Co Ltd Intelligent Electrostatic Sensor AP T ...

Страница 2: ...tion distance can be selected by the DIP switch Adjustable Detection distance A closed loop monitoring and elimination system is formed by electrostatic sensing detection equipment electrostatic elimination equipment power supply equipment display equipment and IMS ionization monitoring system to realize automatic and unmanned electrostatic monitoring and elimination Closed loop Static electricity...

Страница 3: ... and elimination system Terminal power Closed loop electrostatic detection monitoring and elimination system The closed loop electrostatic monitoring and elimination system formed by detection equipment elimination equipment power supply equipment display equipment and IMS Ionization Monitoring System can realize real time monitoring data storage and dynamic display under the control of system sof...

Страница 4: ...ltage range and minimum resolution corresponding to each detection distance Specification two Detection gear Distance coding Detection distance Range Resolution Error Zero runout Calibration 1 0 5mm 2000V 1V 10 1V 1 10mm 4000V 2V 2V 2 2 25mm 20000V 10V 10V 3 50mm 20000V 10V 10V 3 4 100mm 20000V 10V 10V 5 150mm 20000V 10V 10V 4 6 200mm 20000V 10V 10V 7 250mm 20000V 10V 10V 5 8 300mm 20000V 10V 10V ...

Страница 5: ...charged objects The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate Do not adjust zero in the static charge state or in the electrostatic detection proces...

Страница 6: ...onverter net weight about 20 5g The external dimension of the communication converter is as follows Nut Post 100 120 52 76 87 5 14 14 4 25 IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shield P1 P2 P4 P3 Red VTH HVAL ACT Clean Green ACT Work Link NEXT SCAN NEXT LINK B SET S SCROLL T output port 24V DC 1 2 line output ...

Страница 7: ... withstand voltage of the resistance should be 20KV the current passing through the protection resistance and the human body should be 5mA and the resistance value should meet the requirements of the following formula In the formula R is the protection resistance the unit is ohm Ω Rd is the resistance of the insulating support the unit is ohm Ω the resistance value is 1013Ω and the withstand volta...

Страница 8: ...al test data chart of standard plate electrode The test is divided into vertical test and horizontal test The schematic diagram 9 of the sensor test device is as follows The vertical test data of the sensor and the standard plate electrode are as follows 10000 50000 5000 10000 10000 5000 0 5000 10000 Standard voltage slopeK 1 Test distance100mm Test distance300mm Test distance500mm The measured vo...

Страница 9: ...e 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 within the horizontal distance range of 200mm X 200mm under the vertical test distance of 300mm for the 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 ...

Страница 10: ...wer supply for comprehensive on line mode These three network ports of the 24V power adapter the monitoring terminal and the electrostatic sensor are both power ports and communication ports which can be used in common Connection to monitoring terminal Connection to PC IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shi...

Страница 11: ...ring software according to the withstand static voltage value of the protected product Note The threshold alarm indicator light is green when the detected static voltage value is within the set electrostatic threshold value while the light is red when it exceeds the set threshold value Use a Phillips screwdriver with a diameter of 3mm to turn the ADDR circular DIP switch to set the device address ...

Страница 12: ...gh vibration area otherwise data errors may occur Please check the power cable or communication cable of the product regularly and replace it immediately if it is damaged Otherwise it will easily cause problems such as leakage of electricity poor communication and abnormal work It may cause failure when the product suffers from mechanical shocks such as drops bumps etc The whole equipment must be ...

Страница 13: ... according to the use environment and static control requirements 5 Product has an odor Component burn out Return to factory for maintenance 6 Please contact the manufacturer or seller if there are other unlisted problems or the problem cannot be solved through the above solutions Trouble shooting 1 Please store the equipment in a dry place away from light and do not put heavy pressure on it when ...

Страница 14: ...nitoring analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...

Отзывы: