Steps
Installation
①
Use a Phillips screwdriver with a diameter of 3mm to turn the “DIST” circular DIP switch to select the test distance according to the amount of
static electricity carried by the charged object and the use environment.
②
Toggle the "RANGE" circular DIP switch to select the detection gear according to the amount of static electricity carried by the charged object
and the use environment.
③
Set the static electricity safety (alarm) threshold value through the remote control or monitoring software according to the withstand static voltage
value of the protected product.
Note: The threshold alarm indicator light is green when the detected static voltage value is within the set electrostatic threshold value while the
light is red when it exceeds the set threshold value.
④
Use a Phillips screwdriver with a diameter of 3mm to turn the "ADDR" circular DIP switch to set the device address according to the production
station.
Set the sensor detection parameters according to the sensor label description:
Figure 16 Schematic diagram of sensor function
Figure 17 Schematic diagram of sensor installation orientation
Working environment
Working temperature
:
0
℃
→
+
50
℃
Working humidity
:
30 → 65%RH