background image

Precautions

Please read the operating instruction carefully before using the device in order to use it correctly.

Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the specifications may

cause damage or even failure to the product.

Please operate at the specified ambient temperature (0 to 50°C).

Keep a distance of more than 1m between the people and the product to avoid the impact of human static electricity on the test during the test.

Testers must wear electrostatic clothes, electrostatic caps and electrostatic shoes.

The insertion depth of the φ5 diameter stainless steel mounting rod must not exceed the position of the detection switch on the back of the sensor. 

The surface of the φ5 diameter stainless steel mounting rod must not have insulating coating.

Do not touch the electrostatic detection head during detection.

Make sure that the sensor window is free from particulates and dust pollution.

There should be no obstruction between the sensor and the detected object, otherwise the accuracy of the detection result will be affected.

There should be no electrical equipment that affects the sensor within the detection distance of the sensor. Otherwise, the internal equipment and

chip may be failed or damaged.

The plane of the sensor detection window should be parallel to the surface of the object to be measured to measure charged objects accurately.

5 seconds of power connection before use. Otherwise, sometimes the data display will be unstable.

The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate.

The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate.

Do not adjust zero in the state of static charge or during electrostatic measurement(non-electrostatic calibration process). The displayed static value

may be zero if zero is set during static testing.

Do not install the sensor around high-voltage equipment, such as high-voltage power supplies, electrostatic generators, ion generators, and 

eliminators. High voltages will affect the performance and detection accuracy of the sensor.

Tighten the sensor when installing a high-vibration area; otherwise, data errors may occur.

Please check the power cable or communication cable of the product regularly and replace it immediately if it is damaged. Otherwise it will easily

cause problems such as leakage of electricity, poor communication, and abnormal work.

It may cause failure when the product suffers from mechanical shocks such as drops, bumps, etc..

The whole equipment must be reliably grounded during use; Otherwise, it is easy to cause abnormal or even damage.

Do not use the equipment in inflammable and explosive environment.

Do not touch the electrostatic detection window with sharp objects.

The product is strictly prohibited to touch liquid during use, otherwise there will be abnormal, resulting in electric shock or fire.

Exceeding the detection range may result in product failure.

Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

Do not disassemble the detector which is a precision equipment.

It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by professional personnel.

The product is specially designed for detecting static electricity on the surface of objects and is strictly prohibited for other purposes. Any abnormal 

use may machine failure, electric shock, fire and other hidden dangers.

 

Installation and use precautions

Sensor Accessories List

Part name

Standard 

or optional Part No.

Specification

Picture

Application

Black shielded network 

cable with crystal 

connectors at both ends 

(with bag)

Standard

8WXI00004

Super five double shielded 

network cable

Used to connect product power 

supply data interaction

Power Adapter

Standard

AP2930003

Input voltage: AC100-240V

Output voltage: DC24V

Output current: 2A

Output power: 48W

Used for product power supply 

data interaction

National standard

 power cord

Standard

8YXG25110

Standard 1.8m

Optional  3m/5m

Used to connect adapters

Black shielded network 

cable with single-ended 

crystal head -2.5m (with 

bag)

Optional

8WXI00002

Super five double shielded 

single-ended network cable

Used to connect to PLC/machine/

large slitting machine, etc.

Mounting brackets

Standard

AP8038012

40*39*2 waist hole diameter 

5mm, round hole diameter 3.5

Used to fix electrostatic sensors

Infrared remote control

Standard

AP2253002

AP&T Three-in-one panel 

L*W*H=85.76*39.76*6.66

Used to adjust electrostatic sensors

Blower

Bar

Sensor

CAL

S

RZ

V

TH

+

V

TH

-

K

-

K+

I

B

-

I

B

+

T+

T

-

F

R/S

B

R/S

F

Q

+

F

Q

-

I

B

+

I

B

-

F

S

+

F

S

-

RES

Warning

Содержание AP-YV3303

Страница 1: ...Intelligent Electrostatic Sensor AP YV3303 AP TR The second generation Shanghai Anping Static Technology Co Ltd Intelligent Electrostatic Sensor AP T ...

Страница 2: ...tion distance can be selected by the DIP switch Adjustable Detection distance A closed loop monitoring and elimination system is formed by electrostatic sensing detection equipment electrostatic elimination equipment power supply equipment display equipment and IMS ionization monitoring system to realize automatic and unmanned electrostatic monitoring and elimination Closed loop Static electricity...

Страница 3: ... and elimination system Terminal power Closed loop electrostatic detection monitoring and elimination system The closed loop electrostatic monitoring and elimination system formed by detection equipment elimination equipment power supply equipment display equipment and IMS Ionization Monitoring System can realize real time monitoring data storage and dynamic display under the control of system sof...

Страница 4: ...ltage range and minimum resolution corresponding to each detection distance Specification two Detection gear Distance coding Detection distance Range Resolution Error Zero runout Calibration 1 0 5mm 2000V 1V 10 1V 1 10mm 4000V 2V 2V 2 2 25mm 20000V 10V 10V 3 50mm 20000V 10V 10V 3 4 100mm 20000V 10V 10V 5 150mm 20000V 10V 10V 4 6 200mm 20000V 10V 10V 7 250mm 20000V 10V 10V 5 8 300mm 20000V 10V 10V ...

Страница 5: ...charged objects The measured value is smaller than the actual electrostatic value of the charged object when the charged object is smaller than the calibration plate The measured value is larger than the actual electrostatic value of the charged object when the charged object is larger than the calibration plate Do not adjust zero in the static charge state or in the electrostatic detection proces...

Страница 6: ...onverter net weight about 20 5g The external dimension of the communication converter is as follows Nut Post 100 120 52 76 87 5 14 14 4 25 IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shield P1 P2 P4 P3 Red VTH HVAL ACT Clean Green ACT Work Link NEXT SCAN NEXT LINK B SET S SCROLL T output port 24V DC 1 2 line output ...

Страница 7: ... withstand voltage of the resistance should be 20KV the current passing through the protection resistance and the human body should be 5mA and the resistance value should meet the requirements of the following formula In the formula R is the protection resistance the unit is ohm Ω Rd is the resistance of the insulating support the unit is ohm Ω the resistance value is 1013Ω and the withstand volta...

Страница 8: ...al test data chart of standard plate electrode The test is divided into vertical test and horizontal test The schematic diagram 9 of the sensor test device is as follows The vertical test data of the sensor and the standard plate electrode are as follows 10000 50000 5000 10000 10000 5000 0 5000 10000 Standard voltage slopeK 1 Test distance100mm Test distance300mm Test distance500mm The measured vo...

Страница 9: ...e 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 within the horizontal distance range of 200mm X 200mm under the vertical test distance of 300mm for the 600 600mm calibration plate It can be seen from the above two horizontal test charts that the measurement error of the sensor can be kept within 5 ...

Страница 10: ...wer supply for comprehensive on line mode These three network ports of the 24V power adapter the monitoring terminal and the electrostatic sensor are both power ports and communication ports which can be used in common Connection to monitoring terminal Connection to PC IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_VTH HVAL 8 C_ACT Clean 9 PE Metal shi...

Страница 11: ...ring software according to the withstand static voltage value of the protected product Note The threshold alarm indicator light is green when the detected static voltage value is within the set electrostatic threshold value while the light is red when it exceeds the set threshold value Use a Phillips screwdriver with a diameter of 3mm to turn the ADDR circular DIP switch to set the device address ...

Страница 12: ...gh vibration area otherwise data errors may occur Please check the power cable or communication cable of the product regularly and replace it immediately if it is damaged Otherwise it will easily cause problems such as leakage of electricity poor communication and abnormal work It may cause failure when the product suffers from mechanical shocks such as drops bumps etc The whole equipment must be ...

Страница 13: ... according to the use environment and static control requirements 5 Product has an odor Component burn out Return to factory for maintenance 6 Please contact the manufacturer or seller if there are other unlisted problems or the problem cannot be solved through the above solutions Trouble shooting 1 Please store the equipment in a dry place away from light and do not put heavy pressure on it when ...

Страница 14: ...nitoring analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...

Отзывы: