Product specifications and technical functions
1
)
Technical Specifications
:
Specification one
NO.
Basic parameter
1 Working voltage
DC8-24V
2 Working current
<
50mA
3 Sampling time
About 1ms
4 Vibration
<
1KHz
5 Noise
<
5dB
6 Signal output
RS485(115200bps,8,1,n,n)
(
≧
20ms
)
Collector open circuit
(
<50V/100mA
)
7
Network port definition
1
、
2
3
4
5
、
6
、
9
7
8
White-orange/orange White-blue
Blue White-green/green
White-brown Brown
VCC
RS485_B
RS485_A
GND
、
PE
NPN-C1
NPN-C2
8 Communication distance
<
300m
9 Alarm indication
LED
10 Threshold setting range
0
~
±5000V
11 Detection angle
<
15°
12 Test plate size
600mm*600mm
13 Startup test time
5S
14 Infrared controlled range
<
20°
,
1m
※
Product specifications and performance may be changed due to product improvements and upgrades. Please refer to the actual product without prior notice.
2) The static voltage range and minimum resolution corresponding to each detection distance
:
Specification two
Detection
gear
Distance
coding
Detection
distance
Range Resolution Error Zero runout Calibration
1
0
5mm
±2000V
1V
10%
±1V
×
1
10mm
±4000V
2V
±2V
2
2
25mm
±20000V
10V
±10V
3
50mm
±20000V
10V
±10V
3
4
100mm
±20000V
10V
±10V
√
5
150mm
±20000V
10V
±10V
×
4
6
200mm
±20000V
10V
±10V
7
250mm
±20000V
10V
±10V
5
8
300mm
±20000V
10V
±10V
√
9
350mm
±20000V
10V
±10V
×
6
A
400mm
±20000V
10V
±10V
B
450mm
±20000V
10V
±10V
7
C
500mm
±20000V
10V
±10V
√
D
550mm
±20000V
10V
±10V
×
8
E
600mm
±20000V
10V
±10V
F
700mm
±20000V
10V
±10V
※
Product specifications and performance may be changed due to product improvements and upgrades. Please refer to the actual product without prior notice.
Unlock (unlock before debugging)
Customer use
SRZ
:
reset
V
TH
+/V
TH
-
:
Threshold adjustment in 10V unit
30s delay if any key is pressed after unlocking
Exit and re-locked if no key is pressed after unlocking
Product specifications and technical functions ...
3)
Infrared remote control command
technology function
: